Explore Products

My Quote Request

No products added yet

5925-00-024-0864

20 Products

72-317-1MG6

CIRCUIT BREAKER

NSN, MFG P/N

5925000240864

NSN

5925-00-024-0864

View More Info

72-317-1MG6

CIRCUIT BREAKER

NSN, MFG P/N

5925000240864

NSN

5925-00-024-0864

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 14.000 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP FIRST LOCATION SERIES TRIP SECOND LOCATION RELAY TRIP THIRD LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 3.5 AMPERES AC FIRST LOCATION 3.5 AMPERES AC SECOND LOCATION 500.0 MILLIAMPERES AC THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 8 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.300 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

QBH1020

CIRCUIT BREAKER

NSN, MFG P/N

5925000251339

NSN

5925-00-025-1339

View More Info

QBH1020

CIRCUIT BREAKER

NSN, MFG P/N

5925000251339

NSN

5925-00-025-1339

MFG

WESTINGHOUSE ELECTRIC CORP CONTROL BUSINESS UNIT

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY HEIGHT: 2.375 INCHES NOMINAL
BODY LENGTH: 3.375 INCHES NOMINAL
BODY STYLE: 10A SINGLE POLE TYPE
BODY WIDTH: 1.000 INCHES NOMINAL
BOSS HEIGHT: 0.187 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 1 COMPRESSION AND 1 TAB W/SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 120.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL-MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0 SINGLE LOCATION

QNBL1020

CIRCUIT BREAKER

NSN, MFG P/N

5925000251339

NSN

5925-00-025-1339

View More Info

QNBL1020

CIRCUIT BREAKER

NSN, MFG P/N

5925000251339

NSN

5925-00-025-1339

MFG

NORTHROP GRUMMAN-CANADA LTD

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY HEIGHT: 2.375 INCHES NOMINAL
BODY LENGTH: 3.375 INCHES NOMINAL
BODY STYLE: 10A SINGLE POLE TYPE
BODY WIDTH: 1.000 INCHES NOMINAL
BOSS HEIGHT: 0.187 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 1 COMPRESSION AND 1 TAB W/SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 120.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL-MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0 SINGLE LOCATION

ET5739

CIRCUIT BREAKER

NSN, MFG P/N

5925000256005

NSN

5925-00-025-6005

View More Info

ET5739

CIRCUIT BREAKER

NSN, MFG P/N

5925000256005

NSN

5925-00-025-6005

MFG

SPD ELECTRICAL SYSTEMS INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY HEIGHT: 4.062 INCHES NOMINAL
BODY LENGTH: 11.000 INCHES NOMINAL
BODY STYLE: 11B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 9.000 INCHES NOMINAL
BOSS HEIGHT: 0.250 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 9.875 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 3.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 9.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 3.000 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 400.0 AMPERES AC AND 400.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 25000.0 AC AND 20000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 250.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS MAXIMUM ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.250 INCHES NOMINAL

JL3B400

CIRCUIT BREAKER

NSN, MFG P/N

5925000256005

NSN

5925-00-025-6005

View More Info

JL3B400

CIRCUIT BREAKER

NSN, MFG P/N

5925000256005

NSN

5925-00-025-6005

MFG

SIEMENS-ALLIS INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY HEIGHT: 4.062 INCHES NOMINAL
BODY LENGTH: 11.000 INCHES NOMINAL
BODY STYLE: 11B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 9.000 INCHES NOMINAL
BOSS HEIGHT: 0.250 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 9.875 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 3.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 9.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 3.000 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 400.0 AMPERES AC AND 400.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 25000.0 AC AND 20000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 250.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS MAXIMUM ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.250 INCHES NOMINAL

454-0067-004

CIRCUIT BREAKER

NSN, MFG P/N

5925000259282

NSN

5925-00-025-9282

View More Info

454-0067-004

CIRCUIT BREAKER

NSN, MFG P/N

5925000259282

NSN

5925-00-025-9282

MFG

BOEING COMPANY THE DBA BOEING DIV DEFENSE SPACE & SECURITY - NETWORK & SPACE SYSTEMS

Description

DESIGN CONTROL REFERENCE: 454-0067-004
MANUFACTURERS CODE: 94756
POLE QUANTITY: 2
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS: NAVORD OD41152
THE MANUFACTURERS DATA:

184815

CIRCUIT BREAKER

NSN, MFG P/N

5925000261977

NSN

5925-00-026-1977

View More Info

184815

CIRCUIT BREAKER

NSN, MFG P/N

5925000261977

NSN

5925-00-026-1977

MFG

EASTMAN KODAK COMPANY DBA KODAK

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 1C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.500 INCHES NOMINAL
BUSHING LENGTH: 0.130 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.560 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629-9-115
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.660 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.032 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC55629-9
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 4 SCREW
TEST DATA DOCUMENT: 81349-MILC55629-9 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

JA2S-T3-A-000-02E

CIRCUIT BREAKER

NSN, MFG P/N

5925000261977

NSN

5925-00-026-1977

View More Info

JA2S-T3-A-000-02E

CIRCUIT BREAKER

NSN, MFG P/N

5925000261977

NSN

5925-00-026-1977

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 1C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.500 INCHES NOMINAL
BUSHING LENGTH: 0.130 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.560 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629-9-115
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.660 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.032 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC55629-9
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 4 SCREW
TEST DATA DOCUMENT: 81349-MILC55629-9 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

M55629-9-115

CIRCUIT BREAKER

NSN, MFG P/N

5925000261977

NSN

5925-00-026-1977

View More Info

M55629-9-115

CIRCUIT BREAKER

NSN, MFG P/N

5925000261977

NSN

5925-00-026-1977

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 1C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.500 INCHES NOMINAL
BUSHING LENGTH: 0.130 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.560 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629-9-115
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.660 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.032 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC55629-9
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 4 SCREW
TEST DATA DOCUMENT: 81349-MILC55629-9 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

0624A0392

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

View More Info

0624A0392

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

MFG

ARROW-MASTER INCORPORATED

Description

BODY HEIGHT: 1.875 INCHES MAXIMUM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 16A SINGLE POLE TYPE
BODY WIDTH: 1.813 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/1-1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.174 INCHES NOMINAL

12045387

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

View More Info

12045387

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

MFG

BCP CONSTRUCTION PRODUCTS DIV OF TEREX CORP

Description

BODY HEIGHT: 1.875 INCHES MAXIMUM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 16A SINGLE POLE TYPE
BODY WIDTH: 1.813 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/1-1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.174 INCHES NOMINAL

16913P11

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

View More Info

16913P11

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

MFG

M-R-S MFG CO

Description

BODY HEIGHT: 1.875 INCHES MAXIMUM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 16A SINGLE POLE TYPE
BODY WIDTH: 1.813 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/1-1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.174 INCHES NOMINAL

195900

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

View More Info

195900

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

MFG

FWD SEAGRAVE HOLDINGS LP DIV SEAGRAVE FIRE APPARATUS LLC

Description

BODY HEIGHT: 1.875 INCHES MAXIMUM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 16A SINGLE POLE TYPE
BODY WIDTH: 1.813 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/1-1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.174 INCHES NOMINAL

20L10

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

View More Info

20L10

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

MFG

BARBER-GREENE CO

Description

BODY HEIGHT: 1.875 INCHES MAXIMUM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 16A SINGLE POLE TYPE
BODY WIDTH: 1.813 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/1-1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.174 INCHES NOMINAL

22353

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

View More Info

22353

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

MFG

PERFECTION-COBEY CO DIV OF HARSCO CORP

Description

BODY HEIGHT: 1.875 INCHES MAXIMUM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 16A SINGLE POLE TYPE
BODY WIDTH: 1.813 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/1-1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.174 INCHES NOMINAL

375MAF1

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

View More Info

375MAF1

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

MFG

LINDE LIFT TRUCK CORP.

Description

BODY HEIGHT: 1.875 INCHES MAXIMUM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 16A SINGLE POLE TYPE
BODY WIDTH: 1.813 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/1-1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.174 INCHES NOMINAL

3M5999

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

View More Info

3M5999

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

MFG

CATERPILLAR INC. DBA CATERPILLAR DIV GOVERNMENTAL AND DEFENSE PRODUCTS

Description

BODY HEIGHT: 1.875 INCHES MAXIMUM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 16A SINGLE POLE TYPE
BODY WIDTH: 1.813 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/1-1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.174 INCHES NOMINAL

4499

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

View More Info

4499

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

MFG

ELLIOTT MACHINE WORKS INC

Description

BODY HEIGHT: 1.875 INCHES MAXIMUM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 16A SINGLE POLE TYPE
BODY WIDTH: 1.813 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/1-1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.174 INCHES NOMINAL

481525

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

View More Info

481525

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

MFG

AMERICAN HOIST AND DERRICK CO

Description

BODY HEIGHT: 1.875 INCHES MAXIMUM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 16A SINGLE POLE TYPE
BODY WIDTH: 1.813 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/1-1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.174 INCHES NOMINAL

485643

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

View More Info

485643

CIRCUIT BREAKER

NSN, MFG P/N

5925000264767

NSN

5925-00-026-4767

MFG

AMERICAN STANDARD INC WESTINGHOUSE AIR BRAKE CO DIV

Description

BODY HEIGHT: 1.875 INCHES MAXIMUM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 16A SINGLE POLE TYPE
BODY WIDTH: 1.813 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/1-1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.174 INCHES NOMINAL