PDLA-105

CIRCUIT BREAKER

NSN, MFG P/N

5925002955460

NSN

5925-00-295-5460

View More Info

PDLA-105

CIRCUIT BREAKER

NSN, MFG P/N

5925002955460

NSN

5925-00-295-5460

MFG

SENSATA TECHNOLOGIES INC

Description

BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.880 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.060 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/07-009
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.406 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 105.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 3.160 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM

AA55571

CIRCUIT BREAKER

NSN, MFG P/N

5925002955460

NSN

5925-00-295-5460

View More Info

AA55571

CIRCUIT BREAKER

NSN, MFG P/N

5925002955460

NSN

5925-00-295-5460

MFG

FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC

Description

BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.880 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.060 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/07-009
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.406 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 105.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 3.160 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM

M13516/7-9

CIRCUIT BREAKER

NSN, MFG P/N

5925002955460

NSN

5925-00-295-5460

View More Info

M13516/7-9

CIRCUIT BREAKER

NSN, MFG P/N

5925002955460

NSN

5925-00-295-5460

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.880 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.060 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/07-009
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.406 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 105.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 3.160 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM

MS39068-4

CIRCUIT BREAKER

NSN, MFG P/N

5925002955460

NSN

5925-00-295-5460

View More Info

MS39068-4

CIRCUIT BREAKER

NSN, MFG P/N

5925002955460

NSN

5925-00-295-5460

MFG

MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.880 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.060 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/07-009
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.406 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 105.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 3.160 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM

3AA7890

CIRCUIT BREAKER

NSN, MFG P/N

5925002955462

NSN

5925-00-295-5462

View More Info

3AA7890

CIRCUIT BREAKER

NSN, MFG P/N

5925002955462

NSN

5925-00-295-5462

MFG

THALES UK LIMITED, AEROSPACE DIVISION

Description

BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.880 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.060 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/7-7
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.406 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 80.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/7
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 3.160 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/7BII GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM

7392439

CIRCUIT BREAKER

NSN, MFG P/N

5925002955462

NSN

5925-00-295-5462

View More Info

7392439

CIRCUIT BREAKER

NSN, MFG P/N

5925002955462

NSN

5925-00-295-5462

MFG

U S ARMY TANK AUTOMOTIVE COMMAND AMSTA-IM-MM

Description

BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.880 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.060 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/7-7
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.406 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 80.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/7
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 3.160 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/7BII GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM

M13516/7-7

CIRCUIT BREAKER

NSN, MFG P/N

5925002955462

NSN

5925-00-295-5462

View More Info

M13516/7-7

CIRCUIT BREAKER

NSN, MFG P/N

5925002955462

NSN

5925-00-295-5462

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.880 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.060 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/7-7
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.406 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 80.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/7
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 3.160 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/7BII GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM

MS39068-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002955462

NSN

5925-00-295-5462

View More Info

MS39068-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002955462

NSN

5925-00-295-5462

MFG

MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.880 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.060 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/7-7
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.406 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 80.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/7
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 3.160 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13561/7BII GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM

ETM7053

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002955845

NSN

5925-00-295-5845

View More Info

ETM7053

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002955845

NSN

5925-00-295-5845

MFG

SPD ELECTRICAL SYSTEMS INC

Description

BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FEATURES PROVIDED: ADJUSTABLE TRIP RELEASE
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 125.0 AMPERES AC AND 125.0 AMPERES DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 250.0 DC ALL LOCATIONS
OVERALL HEIGHT: 3.750 INCHES NOMINAL
OVERALL LENGTH: 5.500 INCHES NOMINAL
OVERALL WIDTH: 4.625 INCHES NOMINAL
POLE QUANTITY: 2
TERMINAL TYPE AND QUANTITY: 4 SCREW
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

886002

CIRCUIT BREAKER

NSN, MFG P/N

5925002956255

NSN

5925-00-295-6255

View More Info

886002

CIRCUIT BREAKER

NSN, MFG P/N

5925002956255

NSN

5925-00-295-6255

MFG

ITT CORPORATION

Description

ACTUATOR FUNCTION: TRIP W/SEPARATE RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 SLOT
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 45.000 NOMINAL AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 113.0 ALL LOCATIONS

5155-67

CIRCUIT BREAKER

NSN, MFG P/N

5925002968123

NSN

5925-00-296-8123

View More Info

5155-67

CIRCUIT BREAKER

NSN, MFG P/N

5925002968123

NSN

5925-00-296-8123

MFG

RAYTHEON COMPANY DBA RAYTHEON

Description

ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.203 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.766 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.438 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.569 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.164 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 12.500 NOMINAL AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

517134

CIRCUIT BREAKER

NSN, MFG P/N

5925002968123

NSN

5925-00-296-8123

View More Info

517134

CIRCUIT BREAKER

NSN, MFG P/N

5925002968123

NSN

5925-00-296-8123

MFG

BADGER FIRE PROTECTION INC

Description

ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.203 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.766 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.438 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.569 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.164 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 12.500 NOMINAL AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

58289

CIRCUIT BREAKER

NSN, MFG P/N

5925002968123

NSN

5925-00-296-8123

View More Info

58289

CIRCUIT BREAKER

NSN, MFG P/N

5925002968123

NSN

5925-00-296-8123

MFG

HDT TACTICAL SYSTEMS INC.

Description

ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.203 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.766 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.438 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.569 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.164 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 12.500 NOMINAL AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

C6363-1-15

CIRCUIT BREAKER

NSN, MFG P/N

5925002968123

NSN

5925-00-296-8123

View More Info

C6363-1-15

CIRCUIT BREAKER

NSN, MFG P/N

5925002968123

NSN

5925-00-296-8123

MFG

TEXAS INSTRUMENTS INC METALLURGICAL MATERIALS DIV

Description

ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.203 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.766 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.438 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.569 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.164 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 12.500 NOMINAL AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

G1-12071

CIRCUIT BREAKER

NSN, MFG P/N

5925002968123

NSN

5925-00-296-8123

View More Info

G1-12071

CIRCUIT BREAKER

NSN, MFG P/N

5925002968123

NSN

5925-00-296-8123

MFG

EVANS TEMPCON INC.

Description

ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.203 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.766 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.438 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.569 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.164 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 12.500 NOMINAL AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

NLB5

CIRCUIT BREAKER

NSN, MFG P/N

5925002978821

NSN

5925-00-297-8821

View More Info

NLB5

CIRCUIT BREAKER

NSN, MFG P/N

5925002978821

NSN

5925-00-297-8821

MFG

SPD ELECTRICAL SYSTEMS INC

Description

CRITICALITY CODE JUSTIFICATION: ZZZY
DESIGN CONTROL REFERENCE: NLB5
MANUFACTURERS CODE: 30086
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS: MATERIAL WILL BE IN ACCORDANCE WITH NAVICP MECH; ACTIVITY HX QUALITY CONTROL, MANUFACTURING AND TESTING SPECIFICATIONS.
THE MANUFACTURERS DATA:

C6363-2-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002991677

NSN

5925-00-299-1677

View More Info

C6363-2-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002991677

NSN

5925-00-299-1677

MFG

SENSATA TECHNOLOGIES INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.203 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.766 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.438 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 1.850 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: NONTRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 3.0 AMPERES AC AND 3.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 600.0 AC AND 600.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.406 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.164 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 115.0 AC AND 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 130.0 SINGLE LOCATION

G51323L3

CIRCUIT BREAKER

NSN, MFG P/N

5925002991677

NSN

5925-00-299-1677

View More Info

G51323L3

CIRCUIT BREAKER

NSN, MFG P/N

5925002991677

NSN

5925-00-299-1677

MFG

AMERICAN TELEPHONE AND TELEGRAPH CO

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.203 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.766 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.438 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 1.850 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: NONTRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 3.0 AMPERES AC AND 3.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 600.0 AC AND 600.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.406 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.164 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 115.0 AC AND 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 130.0 SINGLE LOCATION

GA51323L3

CIRCUIT BREAKER

NSN, MFG P/N

5925002991677

NSN

5925-00-299-1677

View More Info

GA51323L3

CIRCUIT BREAKER

NSN, MFG P/N

5925002991677

NSN

5925-00-299-1677

MFG

WILDES AIR CONDITIONING CO INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.203 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.766 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.438 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 1.850 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: NONTRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 3.0 AMPERES AC AND 3.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 600.0 AC AND 600.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.406 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.164 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 115.0 AC AND 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 130.0 SINGLE LOCATION

8736

CIRCUIT BREAKER

NSN, MFG P/N

5925002992728

NSN

5925-00-299-2728

View More Info

8736

CIRCUIT BREAKER

NSN, MFG P/N

5925002992728

NSN

5925-00-299-2728

MFG

EATON CORP OPNS & TECHNICAL CENTER

Description

ACTUATOR FUNCTION: TRIP W/SEPARATE RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY STYLE: 14A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.188 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.817 INCHES MAXIMUM
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 2.170 INCHES MAXIMUM
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION