Explore Products

My Quote Request

No products added yet

5925-00-454-6814

20 Products

BACC18R25B

CIRCUIT BREAKER

NSN, MFG P/N

5925004546814

NSN

5925-00-454-6814

View More Info

BACC18R25B

CIRCUIT BREAKER

NSN, MFG P/N

5925004546814

NSN

5925-00-454-6814

MFG

THE BOEING COMPANY DBA BOEING

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.189 INCHES MAXIMUM
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES MAXIMUM
BUSHING LENGTH: 0.250 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.704 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 43.0 GRAMS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES AC AND 25.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3500.0 AC AND 6000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.860 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC AND 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION

352250008493

CIRCUIT BREAKER

NSN, MFG P/N

5925004546870

NSN

5925-00-454-6870

View More Info

352250008493

CIRCUIT BREAKER

NSN, MFG P/N

5925004546870

NSN

5925-00-454-6870

MFG

THALES NEDERLAND

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 2A SINGLE POLE TYPE
BODY WIDTH: 0.625 INCHES MAXIMUM
BUSHING LENGTH: 0.380 INCHES NOMINAL
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.906 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39019-2-80
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.700 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC39019-2
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 0.5 AC AND 0.5 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 120.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 2 WIRE HOOK
TEST DATA DOCUMENT: 81349-MIL-C-39019 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.500 MINIMUM AT 200 PCT AND 0.900 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

M39019-2-80

CIRCUIT BREAKER

NSN, MFG P/N

5925004546870

NSN

5925-00-454-6870

View More Info

M39019-2-80

CIRCUIT BREAKER

NSN, MFG P/N

5925004546870

NSN

5925-00-454-6870

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 2A SINGLE POLE TYPE
BODY WIDTH: 0.625 INCHES MAXIMUM
BUSHING LENGTH: 0.380 INCHES NOMINAL
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.906 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39019-2-80
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.700 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC39019-2
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 0.5 AC AND 0.5 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 120.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 2 WIRE HOOK
TEST DATA DOCUMENT: 81349-MIL-C-39019 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.500 MINIMUM AT 200 PCT AND 0.900 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

251-45111

CIRCUIT BREAKER

NSN, MFG P/N

5925004547839

NSN

5925-00-454-7839

View More Info

251-45111

CIRCUIT BREAKER

NSN, MFG P/N

5925004547839

NSN

5925-00-454-7839

MFG

DANFOSS INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 0.750 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.430 INCHES NOMINAL
BUSHING LENGTH: 0.280 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.500 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH BUTTON
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 300.0 MILLIAMPERES AC AND 300.0 MILLIAMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1.8 AC AND 1.8 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.460 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 24.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, SINGLE THROW, NORMALLY OPEN
SWITCH CURRENT RATING AND TYPE IN AMPS: 0.5 AC AND 0.5 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: PIN
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 24.0 DC
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
THREAD QUANTITY PER INCH: 27
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 70.0 DEG FAHRENHEIT MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

41-06-P30-SI-0.3AMP

CIRCUIT BREAKER

NSN, MFG P/N

5925004547839

NSN

5925-00-454-7839

View More Info

41-06-P30-SI-0.3AMP

CIRCUIT BREAKER

NSN, MFG P/N

5925004547839

NSN

5925-00-454-7839

MFG

OAKLAND INDUSTRIES LTD DBA E-T-A CIRCUIT BREAKERS

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 0.750 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.430 INCHES NOMINAL
BUSHING LENGTH: 0.280 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.500 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH BUTTON
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 300.0 MILLIAMPERES AC AND 300.0 MILLIAMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1.8 AC AND 1.8 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.460 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 24.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, SINGLE THROW, NORMALLY OPEN
SWITCH CURRENT RATING AND TYPE IN AMPS: 0.5 AC AND 0.5 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: PIN
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 24.0 DC
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
THREAD QUANTITY PER INCH: 27
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 70.0 DEG FAHRENHEIT MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

5206693

CIRCUIT BREAKER

NSN, MFG P/N

5925004547839

NSN

5925-00-454-7839

View More Info

5206693

CIRCUIT BREAKER

NSN, MFG P/N

5925004547839

NSN

5925-00-454-7839

MFG

NAVAL SEA SYSTEMS COMMAND

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 0.750 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.430 INCHES NOMINAL
BUSHING LENGTH: 0.280 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.500 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH BUTTON
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 300.0 MILLIAMPERES AC AND 300.0 MILLIAMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1.8 AC AND 1.8 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.460 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 24.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, SINGLE THROW, NORMALLY OPEN
SWITCH CURRENT RATING AND TYPE IN AMPS: 0.5 AC AND 0.5 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: PIN
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 24.0 DC
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
THREAD QUANTITY PER INCH: 27
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 70.0 DEG FAHRENHEIT MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

EF2B015

CIRCUIT BREAKER

NSN, MFG P/N

5925004548033

NSN

5925-00-454-8033

View More Info

EF2B015

CIRCUIT BREAKER

NSN, MFG P/N

5925004548033

NSN

5925-00-454-8033

MFG

SPD ELECTRICAL SYSTEMS INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC AND 15.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 14000.0 AC FIRST LOCATION 18000.0 DC SECOND LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC FIRST LOCATION 250.0 DC SECOND LOCATION
OVERALL HEIGHT: 4.406 INCHES NOMINAL
OVERALL LENGTH: 6.000 INCHES NOMINAL
OVERALL WIDTH: 3.000 INCHES NOMINAL
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 COMPRESSION
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS MAXIMUM ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.164 INCHES NOMINAL

EE3

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925004548068

NSN

5925-00-454-8068

View More Info

EE3

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925004548068

NSN

5925-00-454-8068

MFG

SPD ELECTRICAL SYSTEMS INC

Description

CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT: 6.375 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 11.875 INCHES NOMINAL
CIRCUIT BREAKER CURRENT RATING IN AMPS: 30.0
CIRCUIT BREAKER TYPE AND QUANTITY: 1 TRIPLE POLE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: RAINTIGHT-NEMA TYPE 3R
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 4.875 INCHES NOMINAL
OVERALL HEIGHT: 15.875 INCHES NOMINAL
OVERALL WIDTH: 8.375 INCHES NOMINAL
STANDARD MOUNTING PATTERN DESIGNATOR: 7C 4 POINT-RECTANGULAR
STYLE DESIGNATOR: 6A RECTANGULAR, SURFACE MOUNTING
SURFACE TREATMENT: ENAMEL
UNTHREADED MOUNTING HOLE DIAMETER: 0.188 INCHES NOMINAL

AM12MG6-30-250-54-60

CIRCUIT BREAKER

NSN, MFG P/N

5925004549232

NSN

5925-00-454-9232

View More Info

AM12MG6-30-250-54-60

CIRCUIT BREAKER

NSN, MFG P/N

5925004549232

NSN

5925-00-454-9232

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
BOSS HEIGHT: 0.140 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.938 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.062 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 4.250 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.611 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 4.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

5661D26G32

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925004552181

NSN

5925-00-455-2181

View More Info

5661D26G32

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925004552181

NSN

5925-00-455-2181

MFG

EATON CORPORATION

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 400.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC ALL LOCATIONS
OVERALL HEIGHT: 4.062 INCHES NOMINAL
OVERALL LENGTH: 16.000 INCHES NOMINAL
OVERALL WIDTH: 8.250 INCHES NOMINAL
POLE QUANTITY: 3
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 90.000 MINIMUM AT 200 PCT AND 550.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS MAXIMUM ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.312 INCHES NOMINAL

APL1111-663-1

CIRCUIT BREAKER

NSN, MFG P/N

5925004557733

NSN

5925-00-455-7733

View More Info

APL1111-663-1

CIRCUIT BREAKER

NSN, MFG P/N

5925004557733

NSN

5925-00-455-7733

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.015 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, THREE, AND FOUR LINKED
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 14.800 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: CORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 4 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 100.0 AMPERES DC FIRST LOCATION 100.0 MILLIAMPERES DC SECOND LOCATION 100.0 AMPERES DC THIRD LOCATION 100.0 MILLIAMPERES DC FOURTH LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 8 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.625 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC FIRST LOCATION 65.0 DC SECOND LOCATION 50.0 DC THIRD LOCATION 65.0 DC FOURTH LOCATION
POLE QUANTITY: 4
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 10.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE FOUR
SWITCH TERMINAL TYPE: PIN
TERMINAL TYPE AND QUANTITY: 8 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.700 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT FIRST LOCATION 0.024 MAXIMUM AT 200 PCT SECOND LOCATION 0.024 MAXIMUM AT 200 PCT FOURTH LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY FIRST LOCATION TIME DELAY SECOND LOCATION INSTANTANEOUS THIRD LOCATION TIME DELAY FOURTH LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

AM17-15-120-55-60

CIRCUIT BREAKER

NSN, MFG P/N

5925004558584

NSN

5925-00-455-8584

View More Info

AM17-15-120-55-60

CIRCUIT BREAKER

NSN, MFG P/N

5925004558584

NSN

5925-00-455-8584

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.190 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 4.250 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: EXPLOSION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3500.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.900 MINIMUM AT 200 PCT AND 8.800 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION
ULTIMATE TRIP TIME PER POLE IN SECONDS: 10.000 MINIMUM AND 30.000 MAXIMUM SINGLE LOCATION

DMS 83059B

CIRCUIT BREAKER

NSN, MFG P/N

5925004558584

NSN

5925-00-455-8584

View More Info

DMS 83059B

CIRCUIT BREAKER

NSN, MFG P/N

5925004558584

NSN

5925-00-455-8584

MFG

DLA LAND AND MARITIME

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.190 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 4.250 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: EXPLOSION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3500.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.900 MINIMUM AT 200 PCT AND 8.800 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION
ULTIMATE TRIP TIME PER POLE IN SECONDS: 10.000 MINIMUM AND 30.000 MAXIMUM SINGLE LOCATION

GC885N15B55

CIRCUIT BREAKER

NSN, MFG P/N

5925004558584

NSN

5925-00-455-8584

View More Info

GC885N15B55

CIRCUIT BREAKER

NSN, MFG P/N

5925004558584

NSN

5925-00-455-8584

MFG

NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN AEROSPACE SYSTEMS

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.190 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 4.250 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: EXPLOSION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3500.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.900 MINIMUM AT 200 PCT AND 8.800 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION
ULTIMATE TRIP TIME PER POLE IN SECONDS: 10.000 MINIMUM AND 30.000 MAXIMUM SINGLE LOCATION

AM17-20-208-400-54

CIRCUIT BREAKER

NSN, MFG P/N

5925004560651

NSN

5925-00-456-0651

View More Info

AM17-20-208-400-54

CIRCUIT BREAKER

NSN, MFG P/N

5925004560651

NSN

5925-00-456-0651

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.190 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 4.250 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: EXPLOSION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3500.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 208.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 12.500 MINIMUM AT 200 PCT AND 37.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION

DMS83059B

CIRCUIT BREAKER

NSN, MFG P/N

5925004560651

NSN

5925-00-456-0651

View More Info

DMS83059B

CIRCUIT BREAKER

NSN, MFG P/N

5925004560651

NSN

5925-00-456-0651

MFG

DLA LAND AND MARITIME

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.190 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 4.250 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: EXPLOSION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3500.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 208.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 12.500 MINIMUM AT 200 PCT AND 37.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION

ETN8256

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925004575364

NSN

5925-00-457-5364

View More Info

ETN8256

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925004575364

NSN

5925-00-457-5364

MFG

SPD ELECTRICAL SYSTEMS INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III PRECIOUS MATERIAL: SILVER
III PRECIOUS MATERIAL AND LOCATION: CONTACTS SILVER
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 4.100 POUNDS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MOUNTING FACILITY TYPE AND QUANTITY: 6 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
POLE QUANTITY: 3
TERMINAL TYPE AND QUANTITY: 6 TAB W/SCREW
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION

108441

CIRCUIT BREAKER

NSN, MFG P/N

5925004583146

NSN

5925-00-458-3146

View More Info

108441

CIRCUIT BREAKER

NSN, MFG P/N

5925004583146

NSN

5925-00-458-3146

MFG

ITT TELECOM PRODUCTS CORP NETWORK SYSTEMS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 CONTROL
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
OVERALL HEIGHT: 2.500 INCHES NOMINAL
OVERALL LENGTH: 2.500 INCHES NOMINAL
OVERALL WIDTH: 2.387 INCHES NOMINAL
POLE QUANTITY: 3
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 2.5 AC
SWITCH LOCATION AND POSITION DESIGNATION: EXTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: SOLDER STUD
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 25.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS

AM333HEMG6-50-250VAC400C14

CIRCUIT BREAKER

NSN, MFG P/N

5925004583146

NSN

5925-00-458-3146

View More Info

AM333HEMG6-50-250VAC400C14

CIRCUIT BREAKER

NSN, MFG P/N

5925004583146

NSN

5925-00-458-3146

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 CONTROL
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
OVERALL HEIGHT: 2.500 INCHES NOMINAL
OVERALL LENGTH: 2.500 INCHES NOMINAL
OVERALL WIDTH: 2.387 INCHES NOMINAL
POLE QUANTITY: 3
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 2.5 AC
SWITCH LOCATION AND POSITION DESIGNATION: EXTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: SOLDER STUD
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 25.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS

72-251-1MG6

CIRCUIT BREAKER

NSN, MFG P/N

5925004586267

NSN

5925-00-458-6267

View More Info

72-251-1MG6

CIRCUIT BREAKER

NSN, MFG P/N

5925004586267

NSN

5925-00-458-6267

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.495 INCHES MINIMUM AND 2.505 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.280 INCHES MAXIMUM
BOSS HEIGHT: 0.135 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.933 INCHES MINIMUM AND 1.943 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.730 INCHES MINIMUM AND 0.770 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.057 INCHES MINIMUM AND 2.067 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.730 INCHES MINIMUM AND 0.770 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 14.000 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.630 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 115.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
THREAD PITCH DIAMETERS: 0.1177 TO 0.1214 INCHES
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS