My Quote Request
5925-00-620-5861
20 Products
TN231175
CIRCUIT BREAKER
NSN, MFG P/N
5925006205861
NSN
5925-00-620-5861
MFG
GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY HEIGHT: 4.625 INCHES NOMINAL
BODY LENGTH: 5.000 INCHES NOMINAL
BODY STYLE: 12B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 4.750 INCHES NOMINAL
BOSS HEIGHT: 0.312 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 3.625 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.688 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: 6319482G175L
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 4.250 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.500 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 03497
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 175.0 AMPERES AC AND 175.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC AND 5000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC17588
NONDEFINITIVE SPEC/STD DATA: ALB TYPE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 125.0 AC AND 125.0 DC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
THE MANUFACTURERS DATA:
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 210.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: ANY ACCEPTABLE
Related Searches:
MILC17588
CIRCUIT BREAKER
NSN, MFG P/N
5925006205861
NSN
5925-00-620-5861
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY HEIGHT: 4.625 INCHES NOMINAL
BODY LENGTH: 5.000 INCHES NOMINAL
BODY STYLE: 12B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 4.750 INCHES NOMINAL
BOSS HEIGHT: 0.312 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 3.625 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.688 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: 6319482G175L
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 4.250 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.500 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 03497
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 175.0 AMPERES AC AND 175.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC AND 5000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC17588
NONDEFINITIVE SPEC/STD DATA: ALB TYPE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 125.0 AC AND 125.0 DC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
THE MANUFACTURERS DATA:
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 210.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: ANY ACCEPTABLE
Related Searches:
4MC1-104-10
CIRCUIT BREAKER
NSN, MFG P/N
5925006209023
NSN
5925-00-620-9023
MFG
SENSATA TECHNOLOGIES INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.300 INCHES NOMINAL
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
BOSS HEIGHT: 0.115 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.680 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.060 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 4.000 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 500.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.510 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 3.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION
Related Searches:
1537678-100
COVER,CIRCUIT BREAKER
NSN, MFG P/N
5925006209727
NSN
5925-00-620-9727
MFG
RAYTHEON COMPANY DBA RAYTHEON
Description
COVER,CIRCUIT BREAKER
Related Searches:
TQL2130
CIRCUIT BREAKER
NSN, MFG P/N
5925006210125
NSN
5925-00-621-0125
MFG
GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY HEIGHT: 2.359 INCHES NOMINAL
BODY LENGTH: 3.875 INCHES NOMINAL
BODY STYLE: 6C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.000 INCHES MAXIMUM
BOSS HEIGHT: 0.187 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 8.000 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 CLIP AND 2 COMPRESSION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 18.000 MINIMUM AT 200 PCT AND 125.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS MAXIMUM ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0 ALL LOCATIONS
Related Searches:
1003255-22
CIRCUIT BREAKER
NSN, MFG P/N
5925006210134
NSN
5925-00-621-0134
MFG
L-3 COMMUNICATIONS CORPORATION DIV LINK SIMULATION & TRAINING DIVISION
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY HEIGHT: 2.922 INCHES NOMINAL
BODY LENGTH: 3.281 INCHES NOMINAL
BODY STYLE: 6C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.000 INCHES NOMINAL
BOSS HEIGHT: 0.219 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 5.100 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 BUS BAR
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
475092
CIRCUIT BREAKER
NSN, MFG P/N
5925006210134
NSN
5925-00-621-0134
MFG
PORTA POWER PAK INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY HEIGHT: 2.922 INCHES NOMINAL
BODY LENGTH: 3.281 INCHES NOMINAL
BODY STYLE: 6C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.000 INCHES NOMINAL
BOSS HEIGHT: 0.219 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 5.100 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 BUS BAR
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
E3-064
CIRCUIT BREAKER
NSN, MFG P/N
5925006210134
NSN
5925-00-621-0134
MFG
NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN AEROSPACE SYSTEMS
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY HEIGHT: 2.922 INCHES NOMINAL
BODY LENGTH: 3.281 INCHES NOMINAL
BODY STYLE: 6C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.000 INCHES NOMINAL
BOSS HEIGHT: 0.219 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 5.100 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 BUS BAR
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
THQL2150
CIRCUIT BREAKER
NSN, MFG P/N
5925006210134
NSN
5925-00-621-0134
MFG
GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY HEIGHT: 2.922 INCHES NOMINAL
BODY LENGTH: 3.281 INCHES NOMINAL
BODY STYLE: 6C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.000 INCHES NOMINAL
BOSS HEIGHT: 0.219 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 5.100 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 BUS BAR
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
JL1A2-8-3
CIRCUIT BREAKER
NSN, MFG P/N
5925006220341
NSN
5925-00-622-0341
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
BUSHING LENGTH: 0.312 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.560 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III UNPACKAGED UNIT WEIGHT: 0.156 POUNDS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH BUTTON
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 8.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.093 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 4.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 30.0 DC
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.150 MINIMUM AT 200 PCT AND 1.500 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION
Related Searches:
JL1-A2-A-5-3
CIRCUIT BREAKER
NSN, MFG P/N
5925006220342
NSN
5925-00-622-0342
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 2.500 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 CLIP
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
OVERALL HEIGHT: 1.168 INCHES MINIMUM AND 1.232 INCHES MAXIMUM
OVERALL LENGTH: 4.636 INCHES MINIMUM AND 4.700 INCHES MAXIMUM
OVERALL WIDTH: 1.968 INCHES MINIMUM AND 2.032 INCHES MAXIMUM
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.150 MINIMUM AT 200 PCT AND 1.500 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION
Related Searches:
JL1-A2-A-2-3
CIRCUIT BREAKER
NSN, MFG P/N
5925006220345
NSN
5925-00-622-0345
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 2.500 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 2.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
OVERALL HEIGHT: 1.168 INCHES MINIMUM AND 1.232 INCHES MAXIMUM
OVERALL LENGTH: 4.636 INCHES MINIMUM AND 4.700 INCHES MAXIMUM
OVERALL WIDTH: 1.968 INCHES MINIMUM AND 2.032 INCHES MAXIMUM
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 4.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 30.0 DC
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.150 MINIMUM AT 200 PCT AND 1.500 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION
Related Searches:
JL1-A2-A-4-3
CIRCUIT BREAKER
NSN, MFG P/N
5925006220354
NSN
5925-00-622-0354
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 4.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
OVERALL HEIGHT: 1.168 INCHES MINIMUM AND 1.232 INCHES MAXIMUM
OVERALL LENGTH: 4.636 INCHES MINIMUM AND 4.700 INCHES MAXIMUM
OVERALL WIDTH: 1.968 INCHES MINIMUM AND 2.032 INCHES MAXIMUM
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 5.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 30.0 DC
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.150 MINIMUM AT 200 PCT AND 1.500 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION
Related Searches:
198936-T05SP
BREAKER LIFTING BEA
NSN, MFG P/N
5925006222293
NSN
5925-00-622-2293
MFG
SPD ELECTRICAL SYSTEMS INC
Description
GENERAL CHARACTERISTICS ITEM DESCRIPTION: BREAKER LIFTING BEAM INCLUDES STEEL CHAIN 1; BRAKET WITH MOUNTING CAPABILITIES 1
Related Searches:
199263K1
HANDLE,MANUAL CHARG
NSN, MFG P/N
5925006222294
NSN
5925-00-622-2294
MFG
SPD ELECTRICAL SYSTEMS INC
Description
NONGOVERNMENT DOCUMENT DATA: 30086-199263K1
Related Searches:
31220
CIRCUIT BREAKER
NSN, MFG P/N
5925006240406
NSN
5925-00-624-0406
MFG
I-T-E IMPERIAL CORP SUB OF GOULD INC DISTRIBUTION AND CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 PUSH BUTTON
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 20.000 NOMINAL AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
P220
CIRCUIT BREAKER
NSN, MFG P/N
5925006240406
NSN
5925-00-624-0406
MFG
SPD ELECTRICAL SYSTEMS INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 PUSH BUTTON
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 20.000 NOMINAL AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
976-1-1X21PC3E
TRIPPER,CIRCUIT BREAKER
NSN, MFG P/N
5925006243030
NSN
5925-00-624-3030
976-1-1X21PC3E
TRIPPER,CIRCUIT BREAKER
NSN, MFG P/N
5925006243030
NSN
5925-00-624-3030
MFG
EATON CORP OPNS & TECHNICAL CENTER
Description
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS: 1500.0 TO 3000.0 AC ALL LOCATIONS
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: ETN5329
FEATURES PROVIDED: ADJUSTABLE TRIP RELEASE
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MANUFACTURERS CODE: 30086
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 250.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 5 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
OVERALL HEIGHT: 3.875 INCHES NOMINAL
OVERALL LENGTH: 8.438 INCHES NOMINAL
OVERALL WIDTH: 5.625 INCHES NOMINAL
POLE QUANTITY: 3
TERMINAL TYPE AND QUANTITY: 6 SCREW
THE MANUFACTURERS DATA:
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 25.000 NOMINAL AT 600 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 105.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.203 INCHES MINIMUM AND 0.438 INCHES MAXIMUM
Related Searches:
ETN5329
TRIPPER,CIRCUIT BREAKER
NSN, MFG P/N
5925006243030
NSN
5925-00-624-3030
MFG
SPD ELECTRICAL SYSTEMS INC
Description
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS: 1500.0 TO 3000.0 AC ALL LOCATIONS
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: ETN5329
FEATURES PROVIDED: ADJUSTABLE TRIP RELEASE
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MANUFACTURERS CODE: 30086
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 250.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 5 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
OVERALL HEIGHT: 3.875 INCHES NOMINAL
OVERALL LENGTH: 8.438 INCHES NOMINAL
OVERALL WIDTH: 5.625 INCHES NOMINAL
POLE QUANTITY: 3
TERMINAL TYPE AND QUANTITY: 6 SCREW
THE MANUFACTURERS DATA:
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 25.000 NOMINAL AT 600 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 105.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.203 INCHES MINIMUM AND 0.438 INCHES MAXIMUM
Related Searches:
ETN5300
CIRCUIT BREAKER SUBASSEMBLY
NSN, MFG P/N
5925006243051
NSN
5925-00-624-3051
MFG
SPD ELECTRICAL SYSTEMS INC
Description
OVERALL LENGTH: 12.000 INCHES NOMINAL
OVERALL WIDTH: 9.000 INCHES NOMINAL
SPECIAL FEATURES: FOR 3 POLE,250 AMP,500V BREAKER; MAJOR COMPONENTS: 1 CURRENT LIMITING FUSE HOUSING ASSY; MTG CONFIGURATION: FOUR 9/32 IN. DIA MTG HOLES, 3 IN. BY 9-3/4 IN. MTG CENTERS; OVERALL DEPTH: 6.813 IN. NOM