5925-00-726-9320
20 Products
MS21919DG20
CIRCUIT BREAKER
NSN, MFG P/N
5925007269320
NSN
5925-00-726-9320
MFG
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.500 INCHES NOMINAL
BOSS HEIGHT: 0.140 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.938 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.062 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 0.547 POUNDS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.549 INCHES MINIMUM AND 2.673 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 125.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.150 MINIMUM AT 200 PCT AND 0.500 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
8670121
CIRCUIT BREAKER
NSN, MFG P/N
5925007260100
NSN
5925-00-726-0100
MFG
TRANS-AERO INDUSTRIES INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 2 ALARM
BODY LENGTH: 1.781 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.665 INCHES NOMINAL
BUSHING LENGTH: 0.290 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.500 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 2.000 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND CORROSION RESISTANT AND MOISTURE RESISTANT AND FUNGUS RESISTANT AND SAND RESISTANT AND DUSTTIGHT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 MILLIAMPERES AC AND 50.0 MILLIAMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC AND 2500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.669 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC AND 32.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 7.0 AC AND 7.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TURRET
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 130.0 AC AND 28.0 DC
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 SINGLE LOCATION
Related Searches:
A437009
CIRCUIT BREAKER
NSN, MFG P/N
5925007260100
NSN
5925-00-726-0100
MFG
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 2 ALARM
BODY LENGTH: 1.781 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.665 INCHES NOMINAL
BUSHING LENGTH: 0.290 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.500 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 2.000 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND CORROSION RESISTANT AND MOISTURE RESISTANT AND FUNGUS RESISTANT AND SAND RESISTANT AND DUSTTIGHT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 MILLIAMPERES AC AND 50.0 MILLIAMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC AND 2500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.669 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC AND 32.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 7.0 AC AND 7.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TURRET
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 130.0 AC AND 28.0 DC
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 SINGLE LOCATION
Related Searches:
7973186P3
CIRCUIT BREAKER
NSN, MFG P/N
5925007260122
NSN
5925-00-726-0122
MFG
LOCKHEED MARTIN CORPORATION DBA MS2 DIV MS2 RADAR SYSTEMS
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.250 INCHES NOMINAL
BOSS HEIGHT: 0.140 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.938 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.062 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III ARC QUENCHING METHOD: AIR
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.611 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 208.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.230 MINIMUM AT 200 PCT AND 0.650 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS
Related Searches:
AM333MG3-15-208VAC400-16
CIRCUIT BREAKER
NSN, MFG P/N
5925007260122
NSN
5925-00-726-0122
AM333MG3-15-208VAC400-16
CIRCUIT BREAKER
NSN, MFG P/N
5925007260122
NSN
5925-00-726-0122
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.250 INCHES NOMINAL
BOSS HEIGHT: 0.140 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.938 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.062 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III ARC QUENCHING METHOD: AIR
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.611 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 208.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.230 MINIMUM AT 200 PCT AND 0.650 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS
Related Searches:
APL111F4-153F
CIRCUIT BREAKER
NSN, MFG P/N
5925007260122
NSN
5925-00-726-0122
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.250 INCHES NOMINAL
BOSS HEIGHT: 0.140 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.938 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.062 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III ARC QUENCHING METHOD: AIR
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.611 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 208.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.230 MINIMUM AT 200 PCT AND 0.650 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS
Related Searches:
G330022S1
CIRCUIT BREAKER
NSN, MFG P/N
5925007263258
NSN
5925-00-726-3258
MFG
ITT CORPORATION DBA ITT GILFILLAN
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY HEIGHT: 2.313 INCHES NOMINAL
BODY LENGTH: 3.500 INCHES NOMINAL
BODY STYLE: 10A SINGLE POLE TYPE
BODY WIDTH: 0.969 INCHES NOMINAL
BOSS HEIGHT: 0.188 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DESIGN CONTROL REFERENCE: G330022S1
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND CORROSION RESISTANT
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 24930
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 CLIP
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 125.0 AC SINGLE LOCATION
POLE QUANTITY: 1
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS: SOURCE CONTROLLED ITEM PER GILFILLAN DWG G330022
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 COMPRESSION
THE MANUFACTURERS DATA:
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 210.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL-MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
Related Searches:
FAE36100S
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925007264460
NSN
5925-00-726-4460
MFG
SCHNEIDER ELECTRIC USA INC DBA SCHNEIDER ELECTRIC
Description
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT: 7.031 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 13.500 INCHES NOMINAL
CIRCUIT BREAKER CURRENT RATING IN AMPS: 100.0
CIRCUIT BREAKER TYPE AND QUANTITY: 1 TRIPLE POLE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: GENERAL PURPOSE-NEMA TYPE 1
III CIRCUIT BREAKER IDENTIFICATION: NEF62100R
III CIRCUIT BREAKER MANUFACTURER CODE: 77176
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 600.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 100.0
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 3.812 INCHES NOMINAL
OVERALL HEIGHT: 14.531 INCHES NOMINAL
OVERALL WIDTH: 7.875 INCHES NOMINAL
STANDARD MOUNTING PATTERN DESIGNATOR: 7C 4 POINT-RECTANGULAR
STYLE DESIGNATOR: 5A RECTANGULAR, FLUSH MOUNTING
SURFACE TREATMENT: PAINT
SYSTEM FOR WHICH DESIGNED: THREE WIRE THREE PHASE
UNTHREADED MOUNTING HOLE DIAMETER: 0.344 INCHES NOMINAL
Related Searches:
NEF62100RAND1100
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925007264460
NSN
5925-00-726-4460
MFG
FEDERAL PACIFIC ELECTRIC CO
Description
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT: 7.031 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 13.500 INCHES NOMINAL
CIRCUIT BREAKER CURRENT RATING IN AMPS: 100.0
CIRCUIT BREAKER TYPE AND QUANTITY: 1 TRIPLE POLE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: GENERAL PURPOSE-NEMA TYPE 1
III CIRCUIT BREAKER IDENTIFICATION: NEF62100R
III CIRCUIT BREAKER MANUFACTURER CODE: 77176
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 600.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 100.0
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 3.812 INCHES NOMINAL
OVERALL HEIGHT: 14.531 INCHES NOMINAL
OVERALL WIDTH: 7.875 INCHES NOMINAL
STANDARD MOUNTING PATTERN DESIGNATOR: 7C 4 POINT-RECTANGULAR
STYLE DESIGNATOR: 5A RECTANGULAR, FLUSH MOUNTING
SURFACE TREATMENT: PAINT
SYSTEM FOR WHICH DESIGNED: THREE WIRE THREE PHASE
UNTHREADED MOUNTING HOLE DIAMETER: 0.344 INCHES NOMINAL
Related Searches:
LAE36300G
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925007264464
NSN
5925-00-726-4464
MFG
SCHNEIDER ELECTRIC USA INC.
Description
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT: 23.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 14.250 INCHES NOMINAL
CIRCUIT BREAKER CURRENT RATING IN AMPS: 300.0
CIRCUIT BREAKER TYPE AND QUANTITY: 1 TRIPLE POLE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: GENERAL PURPOSE-NEMA TYPE 1
III CIRCUIT BREAKER IDENTIFICATION: NJL631300R
III CIRCUIT BREAKER MANUFACTURER CODE: 77176
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 600.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 400.0
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 5.312 INCHES NOMINAL
OVERALL HEIGHT: 28.656 INCHES NOMINAL
OVERALL WIDTH: 16.406 INCHES NOMINAL
STANDARD MOUNTING PATTERN DESIGNATOR: 7C 4 POINT-RECTANGULAR
STYLE DESIGNATOR: 5A RECTANGULAR, FLUSH MOUNTING
SURFACE TREATMENT: PAINT
SYSTEM FOR WHICH DESIGNED: THREE WIRE THREE PHASE
UNTHREADED MOUNTING HOLE DIAMETER: 0.344 INCHES NOMINAL
Related Searches:
NJL621300RAND1400
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925007264464
NSN
5925-00-726-4464
NJL621300RAND1400
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925007264464
NSN
5925-00-726-4464
MFG
FEDERAL PACIFIC ELECTRIC CO
Description
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT: 23.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 14.250 INCHES NOMINAL
CIRCUIT BREAKER CURRENT RATING IN AMPS: 300.0
CIRCUIT BREAKER TYPE AND QUANTITY: 1 TRIPLE POLE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: GENERAL PURPOSE-NEMA TYPE 1
III CIRCUIT BREAKER IDENTIFICATION: NJL631300R
III CIRCUIT BREAKER MANUFACTURER CODE: 77176
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 600.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 400.0
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 5.312 INCHES NOMINAL
OVERALL HEIGHT: 28.656 INCHES NOMINAL
OVERALL WIDTH: 16.406 INCHES NOMINAL
STANDARD MOUNTING PATTERN DESIGNATOR: 7C 4 POINT-RECTANGULAR
STYLE DESIGNATOR: 5A RECTANGULAR, FLUSH MOUNTING
SURFACE TREATMENT: PAINT
SYSTEM FOR WHICH DESIGNED: THREE WIRE THREE PHASE
UNTHREADED MOUNTING HOLE DIAMETER: 0.344 INCHES NOMINAL
Related Searches:
LAE36400G
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925007264467
NSN
5925-00-726-4467
MFG
SCHNEIDER ELECTRIC USA INC.
Description
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT: 22.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 15.750 INCHES NOMINAL
CIRCUIT BREAKER CURRENT RATING IN AMPS: 400.0
CIRCUIT BREAKER TYPE AND QUANTITY: 1 TRIPLE POLE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: GENERAL PURPOSE-NEMA TYPE 1
III CIRCUIT BREAKER IDENTIFICATION: NJL621400R
III CIRCUIT BREAKER MANUFACTURER CODE: 77176
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 600.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 400.0
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 5.312 INCHES NOMINAL
OVERALL HEIGHT: 23.656 INCHES NOMINAL
OVERALL WIDTH: 16.406 INCHES NOMINAL
STANDARD MOUNTING PATTERN DESIGNATOR: 7C 4 POINT-RECTANGULAR
STYLE DESIGNATOR: 5A RECTANGULAR, FLUSH MOUNTING
SURFACE TREATMENT: ENAMEL
SYSTEM FOR WHICH DESIGNED: THREE WIRE THREE PHASE
UNTHREADED MOUNTING HOLE DIAMETER: 0.344 INCHES NOMINAL
Related Searches:
NJL621400RAND1400
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925007264467
NSN
5925-00-726-4467
NJL621400RAND1400
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925007264467
NSN
5925-00-726-4467
MFG
FEDERAL PACIFIC ELECTRIC CO
Description
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT: 22.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 15.750 INCHES NOMINAL
CIRCUIT BREAKER CURRENT RATING IN AMPS: 400.0
CIRCUIT BREAKER TYPE AND QUANTITY: 1 TRIPLE POLE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: GENERAL PURPOSE-NEMA TYPE 1
III CIRCUIT BREAKER IDENTIFICATION: NJL621400R
III CIRCUIT BREAKER MANUFACTURER CODE: 77176
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 600.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 400.0
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 5.312 INCHES NOMINAL
OVERALL HEIGHT: 23.656 INCHES NOMINAL
OVERALL WIDTH: 16.406 INCHES NOMINAL
STANDARD MOUNTING PATTERN DESIGNATOR: 7C 4 POINT-RECTANGULAR
STYLE DESIGNATOR: 5A RECTANGULAR, FLUSH MOUNTING
SURFACE TREATMENT: ENAMEL
SYSTEM FOR WHICH DESIGNED: THREE WIRE THREE PHASE
UNTHREADED MOUNTING HOLE DIAMETER: 0.344 INCHES NOMINAL
Related Searches:
2215AND2400
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925007264468
NSN
5925-00-726-4468
MFG
FEDERAL PACIFIC ELECTRIC CO
Description
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT: 14.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 7.000 INCHES NOMINAL
CIRCUIT BREAKER CURRENT RATING IN AMPS: 15.0
CIRCUIT BREAKER TYPE AND QUANTITY: 1 DOUBLE POLE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: GENERAL PURPOSE-NEMA TYPE 1
III CIRCUIT BREAKER IDENTIFICATION: NEF421015R
III CIRCUIT BREAKER MANUFACTURER CODE: 77176
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 600.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 100.0
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 3.812 INCHES NOMINAL
OVERALL HEIGHT: 14.531 INCHES NOMINAL
OVERALL WIDTH: 7.875 INCHES NOMINAL
STANDARD MOUNTING PATTERN DESIGNATOR: 7C 4 POINT-RECTANGULAR
STYLE DESIGNATOR: 5A RECTANGULAR, FLUSH MOUNTING
SURFACE TREATMENT: ENAMEL
SYSTEM FOR WHICH DESIGNED: THREE WIRE THREE PHASE
UNTHREADED MOUNTING HOLE DIAMETER: 0.344 INCHES NOMINAL
Related Searches:
7741830P6
CIRCUIT BREAKER
NSN, MFG P/N
5925007266307
NSN
5925-00-726-6307
MFG
LOCKHEED MARTIN CORPORATION DBA MS2 DIV MS2 RADAR SYSTEMS
Description
ACTUATOR FUNCTION: RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: 7741830P6
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 8.094 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.375 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III PRECIOUS MATERIAL: SILVER
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 03538
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 70.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 15000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED STUD
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC ALL LOCATIONS
OVERALL HEIGHT: 9.380 INCHES NOMINAL
OVERALL LENGTH: 3.380 INCHES NOMINAL
OVERALL WIDTH: 4.130 INCHES NOMINAL
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 SCREW
THE MANUFACTURERS DATA:
THREAD QUANTITY PER INCH: 16
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 150.000 NOMINAL AT 300 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 35.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
JA3A3-20-2
CIRCUIT BREAKER
NSN, MFG P/N
5925007267838
NSN
5925-00-726-7838
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.250 INCHES NOMINAL
BOSS HEIGHT: 0.140 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.938 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.062 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 9.750 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.471 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
704654K1
CIRCUIT BREAKER
NSN, MFG P/N
5925007268048
NSN
5925-00-726-8048
MFG
SPD ELECTRICAL SYSTEMS INC
Description
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
RESET METHOD: MANUAL
Related Searches:
708392T9
CONTROL,DEVICE
NSN, MFG P/N
5925007268085
NSN
5925-00-726-8085
MFG
SPD ELECTRICAL SYSTEMS INC
Description
GENERAL CHARACTERISTICS ITEM DESCRIPTION: 5.500 IN. LG; 5.000 IN. W; 3.000 IN. H; 2 MTG HOLES 0.250 IN. DIA; 120 VAC; 60 FREQ
Related Searches:
2091401-22
CIRCUIT BREAKER
NSN, MFG P/N
5925007269320
NSN
5925-00-726-9320
MFG
NAVAL SEA SYSTEMS COMMAND
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.500 INCHES NOMINAL
BOSS HEIGHT: 0.140 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.938 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.062 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 0.547 POUNDS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.549 INCHES MINIMUM AND 2.673 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 125.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.150 MINIMUM AT 200 PCT AND 0.500 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
71-123-9MG6
CIRCUIT BREAKER
NSN, MFG P/N
5925007269320
NSN
5925-00-726-9320
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.500 INCHES NOMINAL
BOSS HEIGHT: 0.140 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.938 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.062 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 0.547 POUNDS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.549 INCHES MINIMUM AND 2.673 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 125.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.150 MINIMUM AT 200 PCT AND 0.500 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS