My Quote Request
5925-00-929-7718
20 Products
PSA-15
CIRCUIT BREAKER
NSN, MFG P/N
5925009297718
NSN
5925-00-929-7718
MFG
SENSATA TECHNOLOGIES INC
Description
BODY STYLE: 14A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/05-002
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.430 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: A-A-55571/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 2.190 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
Related Searches:
MS39066-2
CIRCUIT BREAKER
NSN, MFG P/N
5925009297718
NSN
5925-00-929-7718
MFG
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
BODY STYLE: 14A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/05-002
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.430 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: A-A-55571/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 2.190 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
Related Searches:
12957123
CIRCUIT BREAKER
NSN, MFG P/N
5925009297719
NSN
5925-00-929-7719
MFG
U S ARMY ARMAMENT RESEARCH & DEVELOPMENT COMMAND
Description
BODY STYLE: 14A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/05-003
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.430 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 2.190 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 58536-AA55571/5 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 58536-AA55571 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
Related Searches:
13207E2942FN31
CIRCUIT BREAKER
NSN, MFG P/N
5925009297719
NSN
5925-00-929-7719
MFG
CECOM LR CENTER
Description
BODY STYLE: 14A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/05-003
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.430 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 2.190 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 58536-AA55571/5 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 58536-AA55571 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
Related Searches:
AA55571/05-003
CIRCUIT BREAKER
NSN, MFG P/N
5925009297719
NSN
5925-00-929-7719
MFG
FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
Description
BODY STYLE: 14A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/05-003
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.430 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 2.190 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 58536-AA55571/5 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 58536-AA55571 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
Related Searches:
M13516/5-3
CIRCUIT BREAKER
NSN, MFG P/N
5925009297719
NSN
5925-00-929-7719
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
BODY STYLE: 14A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/05-003
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.430 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 2.190 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 58536-AA55571/5 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 58536-AA55571 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
Related Searches:
MS39066-3
CIRCUIT BREAKER
NSN, MFG P/N
5925009297719
NSN
5925-00-929-7719
MFG
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
BODY STYLE: 14A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/05-003
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.430 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 2.190 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 58536-AA55571/5 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 58536-AA55571 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
Related Searches:
PSA-20
CIRCUIT BREAKER
NSN, MFG P/N
5925009297719
NSN
5925-00-929-7719
MFG
SENSATA TECHNOLOGIES INC
Description
BODY STYLE: 14A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/05-003
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 58536
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.430 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: AA55571/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 2.190 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 58536-AA55571/5 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 58536-AA55571 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
Related Searches:
X-220025
CIRCUIT BREAKER
NSN, MFG P/N
5925009297725
NSN
5925-00-929-7725
MFG
ROCKWELL AUTOMATION INC.
Description
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
RESET METHOD: MANUAL
Related Searches:
C66164-1
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925009297829
NSN
5925-00-929-7829
MFG
DLA LAND AND MARITIME OPNS SUPPORT GROUP STANDARDIZATION UNIT
Description
CIRCUIT BREAKER CURRENT RATING IN AMPS: 20.0
CIRCUIT BREAKER TYPE AND QUANTITY: 4 SINGLE POLE
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: C66164-1
DISTANCE BETWEEN MOUNTING FACILITY CENTERS: 8.250 INCHES NOMINAL
FEATURES PROVIDED: COVER
GROUND CONNECTION TYPE FOR WHICH DESIGNED: SOLID
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: GENERAL PURPOSE-NEMA TYPE 1
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 240.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 60.0
MANUFACTURERS CODE: 037Z3
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 4.500 INCHES MAXIMUM
OVERALL HEIGHT: 11.500 INCHES MAXIMUM
OVERALL WIDTH: 9.000 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
STANDARD MOUNTING PATTERN DESIGNATOR: 1C 2 POINT-IN-LINE
STYLE DESIGNATOR: 6A RECTANGULAR, SURFACE MOUNTING
SURFACE TREATMENT: PAINT
SYSTEM FOR WHICH DESIGNED: THREE WIRE SINGLE PHASE
UNTHREADED MOUNTING HOLE DIAMETER: 0.250 INCHES NOMINAL
Related Searches:
9995643-2
CIRCUIT BREAKER
NSN, MFG P/N
5925009302265
NSN
5925-00-930-2265
MFG
U S ARMY AVIATION AND MISSILE COMMAND
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS: 2100.0 TO 7000.0 AC AND 2100.0 TO 7000.0 DC ALL LOCATIONS
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 CONTROL
BODY LENGTH: 15.470 INCHES MINIMUM AND 15.530 INCHES MAXIMUM
BODY STYLE: 17B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 8.220 INCHES MINIMUM AND 8.280 INCHES MAXIMUM
BOSS HEIGHT: 0.350 INCHES MINIMUM AND 0.410 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 11.590 INCHES MINIMUM AND 11.650 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 14.220 INCHES MINIMUM AND 14.280 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM
FEATURES PROVIDED: ADJUSTABLE TRIP RELEASE
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III PRECIOUS MATERIAL: SILVER
III PRECIOUS MATERIAL AND LOCATION: CONTACTS SILVER
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: HERMETICALLY SEALED AND WEATHERPROOF
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 700.0 AMPERES AC AND 700.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 25000.0 AC AND 65000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 10.970 INCHES MINIMUM AND 11.030 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 125.0 DC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: DOUBLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 6.0 AC AND 0.5 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE THREE
SWITCH TERMINAL TYPE: WIRE LEAD
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 600.0 AC AND 125.0 DC
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.340 INCHES MINIMUM AND 0.400 INCHES MAXIMUM
Related Searches:
THKMTKM11-836700
CIRCUIT BREAKER
NSN, MFG P/N
5925009302265
NSN
5925-00-930-2265
MFG
GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS: 2100.0 TO 7000.0 AC AND 2100.0 TO 7000.0 DC ALL LOCATIONS
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 CONTROL
BODY LENGTH: 15.470 INCHES MINIMUM AND 15.530 INCHES MAXIMUM
BODY STYLE: 17B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 8.220 INCHES MINIMUM AND 8.280 INCHES MAXIMUM
BOSS HEIGHT: 0.350 INCHES MINIMUM AND 0.410 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 11.590 INCHES MINIMUM AND 11.650 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 14.220 INCHES MINIMUM AND 14.280 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM
FEATURES PROVIDED: ADJUSTABLE TRIP RELEASE
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III PRECIOUS MATERIAL: SILVER
III PRECIOUS MATERIAL AND LOCATION: CONTACTS SILVER
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: HERMETICALLY SEALED AND WEATHERPROOF
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 700.0 AMPERES AC AND 700.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 25000.0 AC AND 65000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 10.970 INCHES MINIMUM AND 11.030 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 125.0 DC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: DOUBLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 6.0 AC AND 0.5 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE THREE
SWITCH TERMINAL TYPE: WIRE LEAD
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 600.0 AC AND 125.0 DC
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.340 INCHES MINIMUM AND 0.400 INCHES MAXIMUM
Related Searches:
C66004-6
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925009305558
NSN
5925-00-930-5558
MFG
DLA LAND AND MARITIME OPNS SUPPORT GROUP STANDARDIZATION UNIT
Description
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT: 5.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 8.500 INCHES NOMINAL
CIRCUIT BREAKER CURRENT RATING IN AMPS: 20.0
CIRCUIT BREAKER TYPE AND QUANTITY: 1 SINGLE POLE
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: C66004-6
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: WEATHERPROOF-NEMA TYPE 3
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 240.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 50.0
MANUFACTURERS CODE: 037Z3
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 5.000 INCHES NOMINAL
OVERALL HEIGHT: 10.500 INCHES NOMINAL
OVERALL WIDTH: 7.000 INCHES NOMINAL
SPEC/STD CONTROLLING DATA:
STANDARD MOUNTING PATTERN DESIGNATOR: 5C 3 POINT-TRIANGULAR
STYLE DESIGNATOR: 4A SQUARE, SURFACE MOUNTING
SURFACE TREATMENT: PAINT
SYSTEM FOR WHICH DESIGNED: THREE WIRE SINGLE PHASE
UNTHREADED MOUNTING HOLE DIAMETER: 0.250 INCHES NOMINAL
Related Searches:
C66004-7
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925009305559
NSN
5925-00-930-5559
MFG
DLA LAND AND MARITIME OPNS SUPPORT GROUP STANDARDIZATION UNIT
Description
CIRCUIT BREAKER CURRENT RATING IN AMPS: 30.0
CIRCUIT BREAKER TYPE AND QUANTITY: 2 SINGLE POLE
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: C66004-7
DISTANCE BETWEEN MOUNTING FACILITY CENTERS: 7.250 INCHES NOMINAL
FEATURES PROVIDED: COVER
GROUND CONNECTION TYPE FOR WHICH DESIGNED: SOLID
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: GENERAL PURPOSE-NEMA TYPE 1
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 240.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 50.0
MANUFACTURERS CODE: 037Z3
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 5.000 INCHES MAXIMUM
OVERALL HEIGHT: 10.500 INCHES MAXIMUM
OVERALL WIDTH: 7.000 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
STANDARD MOUNTING PATTERN DESIGNATOR: 1C 2 POINT-IN-LINE
STYLE DESIGNATOR: 6A RECTANGULAR, SURFACE MOUNTING
SURFACE TREATMENT: PAINT
SYSTEM FOR WHICH DESIGNED: THREE WIRE SINGLE PHASE
UNTHREADED MOUNTING HOLE DIAMETER: 0.250 INCHES NOMINAL
Related Searches:
26072-1
CIRCUIT BREAKER
NSN, MFG P/N
5925009308948
NSN
5925-00-930-8948
MFG
HEYER PRODUCTS CO INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY HEIGHT: 2.687 INCHES NOMINAL
BODY LENGTH: 5.250 INCHES NOMINAL
BODY STYLE: 9B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 3.000 INCHES NOMINAL
BOSS HEIGHT: 0.218 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 4.359 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 4.359 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.000 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 1.812 POUNDS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: ANY ACCEPTABLE ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC AND 5000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
NOMINAL THREAD SIZE: 0.190 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 40.000 MINIMUM AT 200 PCT AND
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
62-467BMG4
CIRCUIT BREAKER
NSN, MFG P/N
5925009308948
NSN
5925-00-930-8948
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY HEIGHT: 2.687 INCHES NOMINAL
BODY LENGTH: 5.250 INCHES NOMINAL
BODY STYLE: 9B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 3.000 INCHES NOMINAL
BOSS HEIGHT: 0.218 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 4.359 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 4.359 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.000 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 1.812 POUNDS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: ANY ACCEPTABLE ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC AND 5000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
NOMINAL THREAD SIZE: 0.190 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 40.000 MINIMUM AT 200 PCT AND
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
2XAM17-25-120VAC60C55
CIRCUIT BREAKER
NSN, MFG P/N
5925009310315
NSN
5925-00-931-0315
2XAM17-25-120VAC60C55
CIRCUIT BREAKER
NSN, MFG P/N
5925009310315
NSN
5925-00-931-0315
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 1C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.510 INCHES MINIMUM AND 1.530 INCHES MAXIMUM
BUSHING LENGTH: 0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.180 INCHES MINIMUM AND 1.200 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.802 INCHES MINIMUM AND 1.822 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3500.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.800 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
840725
CIRCUIT BREAKER
NSN, MFG P/N
5925009310315
NSN
5925-00-931-0315
MFG
BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 1C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.510 INCHES MINIMUM AND 1.530 INCHES MAXIMUM
BUSHING LENGTH: 0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.180 INCHES MINIMUM AND 1.200 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.802 INCHES MINIMUM AND 1.822 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3500.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.800 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
DMS 83059B
CIRCUIT BREAKER
NSN, MFG P/N
5925009310315
NSN
5925-00-931-0315
MFG
DLA LAND AND MARITIME
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 1C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.510 INCHES MINIMUM AND 1.530 INCHES MAXIMUM
BUSHING LENGTH: 0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.180 INCHES MINIMUM AND 1.200 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.802 INCHES MINIMUM AND 1.822 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3500.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.800 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
4001-002-2
CIRCUIT BREAKER
NSN, MFG P/N
5925009311773
NSN
5925-00-931-1773
MFG
EATON CORPORATION DBA FLUID POWER DIV DIV POWER AND LOAD MANAGEMENT SYSTEMS USE CAGE CODE 81640 FOR CATALOGING.
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.531 INCHES MINIMUM AND 0.593 INCHES MAXIMUM
BUSHING LENGTH: 0.219 INCHES MINIMUM AND 0.281 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.672 INCHES MINIMUM AND 0.734 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III ARC QUENCHING METHOD: AIR
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 38.0 GRAMS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT AND VIBRATIONPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 2.0 AMPERES AC AND 2.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC AND 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.919 INCHES MINIMUM AND 1.981 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 200.0 AC AND 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 120.0 SINGLE LOCATION