Explore Products

My Quote Request

No products added yet

5925-01-265-7690

20 Products

M55629/5-123

CIRCUIT BREAKER

NSN, MFG P/N

5925012657690

NSN

5925-01-265-7690

View More Info

M55629/5-123

CIRCUIT BREAKER

NSN, MFG P/N

5925012657690

NSN

5925-01-265-7690

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.156 INCHES MINIMUM AND 2.344 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/5-123
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 35.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/5 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.130 MINIMUM AT 200 PCT AND 1.600 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

ETN5321A

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925012650314

NSN

5925-01-265-0314

View More Info

ETN5321A

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925012650314

NSN

5925-01-265-0314

MFG

SPD ELECTRICAL SYSTEMS INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS: 1500.0 TO 3000.0 AC ALL LOCATIONS
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
CRITICALITY CODE JUSTIFICATION: FEAT
FEATURES PROVIDED: ADJUSTABLE TRIP RELEASE
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 125.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
OVERALL HEIGHT: 6.812 INCHES NOMINAL
OVERALL LENGTH: 12.000 INCHES NOMINAL
OVERALL WIDTH: 9.000 INCHES NOMINAL
POLE QUANTITY: 3
SPECIAL FEATURES: FOR USE WITH NEW STYLE A FUSE ONLY
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.203 INCHES NOMINAL

JA2-A3A3-A-10-2

CIRCUIT BREAKER

NSN, MFG P/N

5925012650827

NSN

5925-01-265-0827

View More Info

JA2-A3A3-A-10-2

CIRCUIT BREAKER

NSN, MFG P/N

5925012650827

NSN

5925-01-265-0827

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.468 INCHES MINIMUM AND 1.532 INCHES MAXIMUM
BOSS HEIGHT: 0.125 INCHES MINIMUM AND 0.135 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.555 INCHES MINIMUM AND 1.565 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.655 INCHES MINIMUM AND 1.665 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.835 INCHES MINIMUM AND 1.845 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 TAB, SOLDER LUG
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

203-2-1-62-502-4-1-13

CIRCUIT BREAKER

NSN, MFG P/N

5925012650828

NSN

5925-01-265-0828

View More Info

203-2-1-62-502-4-1-13

CIRCUIT BREAKER

NSN, MFG P/N

5925012650828

NSN

5925-01-265-0828

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

BODY STYLE: 5A SINGLE POLE TYPE
BOSS HEIGHT: 0.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.250 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 50.0 OR 60.0 SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 TERMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.770 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC SINGLE LOCATION
OVERALL LENGTH: 1.610 INCHES NOMINAL
OVERALL WIDTH: 0.920 INCHES NOMINAL
POLE QUANTITY: 1
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION

48345-001

CIRCUIT BREAKER

NSN, MFG P/N

5925012650828

NSN

5925-01-265-0828

View More Info

48345-001

CIRCUIT BREAKER

NSN, MFG P/N

5925012650828

NSN

5925-01-265-0828

MFG

ROCKWELL COLLINS DEUTSCHLAND GMBH

Description

BODY STYLE: 5A SINGLE POLE TYPE
BOSS HEIGHT: 0.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.250 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 50.0 OR 60.0 SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 TERMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.770 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC SINGLE LOCATION
OVERALL LENGTH: 1.610 INCHES NOMINAL
OVERALL WIDTH: 0.920 INCHES NOMINAL
POLE QUANTITY: 1
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION

203-11-2-51F-102-1-1

CIRCUIT BREAKER

NSN, MFG P/N

5925012650829

NSN

5925-01-265-0829

View More Info

203-11-2-51F-102-1-1

CIRCUIT BREAKER

NSN, MFG P/N

5925012650829

NSN

5925-01-265-0829

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

BODY LENGTH: 1.610 INCHES NOMINAL
BODY STYLE: 3B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.320 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 8 TERMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.770 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 32.0 DC ALL LOCATIONS
POLE QUANTITY: 2
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS

203-11-2-61F-102-1-1

CIRCUIT BREAKER

NSN, MFG P/N

5925012650830

NSN

5925-01-265-0830

View More Info

203-11-2-61F-102-1-1

CIRCUIT BREAKER

NSN, MFG P/N

5925012650830

NSN

5925-01-265-0830

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

BODY LENGTH: 1.610 INCHES NOMINAL
BODY STYLE: 3B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.320 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 8 TERMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.770 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC ALL LOCATIONS
POLE QUANTITY: 2

203-11-2-61F-502-1-1

CIRCUIT BREAKER

NSN, MFG P/N

5925012650831

NSN

5925-01-265-0831

View More Info

203-11-2-61F-502-1-1

CIRCUIT BREAKER

NSN, MFG P/N

5925012650831

NSN

5925-01-265-0831

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

BODY LENGTH: 1.610 INCHES NOMINAL
BODY STYLE: 3B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.320 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 8 TERMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.770 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC ALL LOCATIONS
POLE QUANTITY: 2

AM3-Z397-2

CIRCUIT BREAKER

NSN, MFG P/N

5925012650832

NSN

5925-01-265-0832

View More Info

AM3-Z397-2

CIRCUIT BREAKER

NSN, MFG P/N

5925012650832

NSN

5925-01-265-0832

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.240 INCHES MINIMUM AND 2.251 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: RELAY TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC AND 15.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC AND 2000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 28.0 DC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
THREAD SERIES DESIGNATOR: UNC
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 130.0 ALL LOCATIONS

F151311-5

CIRCUIT BREAKER

NSN, MFG P/N

5925012654679

NSN

5925-01-265-4679

View More Info

F151311-5

CIRCUIT BREAKER

NSN, MFG P/N

5925012654679

NSN

5925-01-265-4679

MFG

AMERICAN DEVELOPMENT CORP

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY HEIGHT: 2.310 INCHES NOMINAL
BODY LENGTH: 2.940 INCHES NOMINAL
BODY STYLE: 20B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 2.230 INCHES NOMINAL
BOSS HEIGHT: 0.160 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 60.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 CLIP
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 COMPRESSION
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL-MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

QOB160

CIRCUIT BREAKER

NSN, MFG P/N

5925012654679

NSN

5925-01-265-4679

View More Info

QOB160

CIRCUIT BREAKER

NSN, MFG P/N

5925012654679

NSN

5925-01-265-4679

MFG

SCHNEIDER ELECTRIC USA INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY HEIGHT: 2.310 INCHES NOMINAL
BODY LENGTH: 2.940 INCHES NOMINAL
BODY STYLE: 20B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 2.230 INCHES NOMINAL
BOSS HEIGHT: 0.160 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 60.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 CLIP
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 COMPRESSION
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL-MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

M55629/1-055

CIRCUIT BREAKER

NSN, MFG P/N

5925012657680

NSN

5925-01-265-7680

View More Info

M55629/1-055

CIRCUIT BREAKER

NSN, MFG P/N

5925012657680

NSN

5925-01-265-7680

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.730 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/1-055
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 6.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.150 MINIMUM AT 200 PCT AND 1.900 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

M55629/2-040

CIRCUIT BREAKER

NSN, MFG P/N

5925012657681

NSN

5925-01-265-7681

View More Info

M55629/2-040

CIRCUIT BREAKER

NSN, MFG P/N

5925012657681

NSN

5925-01-265-7681

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.730 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/2-040
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 4.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.800 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/2
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/2 GOVERNMENT SPECIFICATION
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 2.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.100 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION

M55629/2-051

CIRCUIT BREAKER

NSN, MFG P/N

5925012657682

NSN

5925-01-265-7682

View More Info

M55629/2-051

CIRCUIT BREAKER

NSN, MFG P/N

5925012657682

NSN

5925-01-265-7682

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
ARC QUENCHING METHOD: MAGNETIC BLOWOUT
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.730 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
FRAGILITY FACTOR: MODERATELY RUGGED
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 6.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.800 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/2 GOVERNMENT SPECIFICATION
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 2.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.130 MINIMUM AT 200 PCT AND 1.400 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0

M55629/2-072

CIRCUIT BREAKER

NSN, MFG P/N

5925012657683

NSN

5925-01-265-7683

View More Info

M55629/2-072

CIRCUIT BREAKER

NSN, MFG P/N

5925012657683

NSN

5925-01-265-7683

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.730 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/2-072
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 9.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.800 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-55629/2
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/2 GOVERNMENT SPECIFICATION
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 2.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.130 MINIMUM AT 200 PCT AND 1.400 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

M55629/3-074

CIRCUIT BREAKER

NSN, MFG P/N

5925012657684

NSN

5925-01-265-7684

View More Info

M55629/3-074

CIRCUIT BREAKER

NSN, MFG P/N

5925012657684

NSN

5925-01-265-7684

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.437 INCHES MINIMUM AND 1.563 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/3-074
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 9.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/3
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/3 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.130 MINIMUM AT 200 PCT AND 1.600 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

M55629/3-120

CIRCUIT BREAKER

NSN, MFG P/N

5925012657685

NSN

5925-01-265-7685

View More Info

M55629/3-120

CIRCUIT BREAKER

NSN, MFG P/N

5925012657685

NSN

5925-01-265-7685

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.437 INCHES MINIMUM AND 1.563 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/3-120
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 35.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/3
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/3 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.600 MINIMUM AT 200 PCT AND 0.800 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

M55629/4-003

CIRCUIT BREAKER

NSN, MFG P/N

5925012657686

NSN

5925-01-265-7686

View More Info

M55629/4-003

CIRCUIT BREAKER

NSN, MFG P/N

5925012657686

NSN

5925-01-265-7686

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.437 INCHES MINIMUM AND 1.563 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/4-003
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 200.0 MILLIAMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.800 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/4
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/4 GOVERNMENT SPECIFICATION
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 2.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

M55629/4-026

CIRCUIT BREAKER

NSN, MFG P/N

5925012657687

NSN

5925-01-265-7687

View More Info

M55629/4-026

CIRCUIT BREAKER

NSN, MFG P/N

5925012657687

NSN

5925-01-265-7687

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.437 INCHES MINIMUM AND 1.563 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/4-026
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 2.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.800 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/4
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/4 GOVERNMENT SPECIFICATION
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 2.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.150 MINIMUM AT 200 PCT AND 1.900 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS

M55629/4-038

CIRCUIT BREAKER

NSN, MFG P/N

5925012657689

NSN

5925-01-265-7689

View More Info

M55629/4-038

CIRCUIT BREAKER

NSN, MFG P/N

5925012657689

NSN

5925-01-265-7689

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.437 INCHES MINIMUM AND 1.563 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/4-038
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 4.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.800 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/4
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/4 GOVERNMENT SPECIFICATION
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 2.00 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE TWO
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS