Explore Products

My Quote Request

No products added yet

5925-01-323-5261

20 Products

ETN9206

CIRCUIT BREAKER

NSN, MFG P/N

5925013235261

NSN

5925-01-323-5261

View More Info

ETN9206

CIRCUIT BREAKER

NSN, MFG P/N

5925013235261

NSN

5925-01-323-5261

MFG

ELECTRO-MECH OF VIRGINIA INC

Description

DESIGN CONTROL REFERENCE: ETN9206
III END ITEM IDENTIFICATION: CIRCUIT BREAKER ACB 100 FR,15 TPP
MANUFACTURERS CODE: 4X584
THE MANUFACTURERS DATA:

41-2-P10-LN2-10A

CIRCUIT BREAKER

NSN, MFG P/N

5925013230907

NSN

5925-01-323-0907

View More Info

41-2-P10-LN2-10A

CIRCUIT BREAKER

NSN, MFG P/N

5925013230907

NSN

5925-01-323-0907

MFG

OAKLAND INDUSTRIES LTD DBA E-T-A CIRCUIT BREAKERS

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.220 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.710 INCHES NOMINAL
BUSHING LENGTH: 0.250 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: HUMIDITY RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH BUTTON
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.130 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPECIAL FEATURES: UTILIZED ON GENERATOR SET,15KW TRAILER MTD,NSN6115013048184
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 70.0 DEG FAHRENHEIT NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0 SINGLE LOCATION

90960

CIRCUIT BREAKER

NSN, MFG P/N

5925013230907

NSN

5925-01-323-0907

View More Info

90960

CIRCUIT BREAKER

NSN, MFG P/N

5925013230907

NSN

5925-01-323-0907

MFG

STEWART & STEVENSON POWER PRODUCTS LLC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.220 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.710 INCHES NOMINAL
BUSHING LENGTH: 0.250 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: HUMIDITY RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH BUTTON
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.130 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPECIAL FEATURES: UTILIZED ON GENERATOR SET,15KW TRAILER MTD,NSN6115013048184
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 70.0 DEG FAHRENHEIT NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0 SINGLE LOCATION

131-1899-00

CIRCUIT BREAKER

NSN, MFG P/N

5925013231468

NSN

5925-01-323-1468

View More Info

131-1899-00

CIRCUIT BREAKER

NSN, MFG P/N

5925013231468

NSN

5925-01-323-1468

MFG

TEKTRONIX INC. DBA TEKTRONIX

XUL-603-018

CIRCUIT BREAKER

NSN, MFG P/N

5925013231468

NSN

5925-01-323-1468

View More Info

XUL-603-018

CIRCUIT BREAKER

NSN, MFG P/N

5925013231468

NSN

5925-01-323-1468

MFG

SL INDUSTRIES INC

704060-711661

CIRCUIT BREAKER

NSN, MFG P/N

5925013231611

NSN

5925-01-323-1611

View More Info

704060-711661

CIRCUIT BREAKER

NSN, MFG P/N

5925013231611

NSN

5925-01-323-1611

MFG

SPD ELECTRICAL SYSTEMS INC

Description

CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: 704060-711661
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III END ITEM IDENTIFICATION: CIRCUIT BREAKERS
MANUFACTURERS CODE: 30086
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
POLE QUANTITY: 3
SPECIAL FEATURES: TRIP AMP 1400,MANUAL OPERATION
THE MANUFACTURERS DATA:

NZM6B-63/ZM6-2.1-12-

CIRCUIT BREAKER

NSN, MFG P/N

5925013231612

NSN

5925-01-323-1612

View More Info

NZM6B-63/ZM6-2.1-12-

CIRCUIT BREAKER

NSN, MFG P/N

5925013231612

NSN

5925-01-323-1612

MFG

KLOCKNER-MOELLER CORP

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY HEIGHT: 110.0 MILLIMETERS NOMINAL
BODY LENGTH: 280.5 MILLIMETERS NOMINAL
BODY STYLE: 12B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 252.0 MILLIMETERS NOMINAL
BOSS HEIGHT: 16.0 MILLIMETERS NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 252.0 MILLIMETERS NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 95.0 MILLIMETERS NOMINAL
CIRCUIT PROTECTION TYPE: UNDERVOLTAGE ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 210.0 MILLIMETERS NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 66.0 MILLIMETERS NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 ROTARY
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 2.1 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 14000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

302-99-001

CIRCUIT BREAKER

NSN, MFG P/N

5925013231613

NSN

5925-01-323-1613

View More Info

302-99-001

CIRCUIT BREAKER

NSN, MFG P/N

5925013231613

NSN

5925-01-323-1613

MFG

WESTWOOD CORPORATION DBA NMP DIVISION DIV NMP DIVISION

702-S0124

CIRCUIT BREAKER

NSN, MFG P/N

5925013231613

NSN

5925-01-323-1613

View More Info

702-S0124

CIRCUIT BREAKER

NSN, MFG P/N

5925013231613

NSN

5925-01-323-1613

MFG

BABCOCK INC.

SM600BA5A12

CIRCUIT BREAKER

NSN, MFG P/N

5925013231613

NSN

5925-01-323-1613

View More Info

SM600BA5A12

CIRCUIT BREAKER

NSN, MFG P/N

5925013231613

NSN

5925-01-323-1613

MFG

EATON CORPORATION DBA FLUID POWER DIV DIV POWER AND LOAD MANAGEMENT SYSTEMS

10075-1017

CIRCUIT BREAKER

NSN, MFG P/N

5925013232207

NSN

5925-01-323-2207

View More Info

10075-1017

CIRCUIT BREAKER

NSN, MFG P/N

5925013232207

NSN

5925-01-323-2207

MFG

HARRIS CORPORATION DBA HARRIS RF COMMUNICATION

139C4621G5

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925013232218

NSN

5925-01-323-2218

View More Info

139C4621G5

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925013232218

NSN

5925-01-323-2218

MFG

GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL

TED UV2BS

CIRCUIT BREAKER

NSN, MFG P/N

5925013232317

NSN

5925-01-323-2317

View More Info

TED UV2BS

CIRCUIT BREAKER

NSN, MFG P/N

5925013232317

NSN

5925-01-323-2317

MFG

GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL

TFK 236200X2

CIRCUIT BREAKER

NSN, MFG P/N

5925013232318

NSN

5925-01-323-2318

View More Info

TFK 236200X2

CIRCUIT BREAKER

NSN, MFG P/N

5925013232318

NSN

5925-01-323-2318

MFG

GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL

TFK UVA2RS

CIRCUIT BREAKER

NSN, MFG P/N

5925013232319

NSN

5925-01-323-2319

View More Info

TFK UVA2RS

CIRCUIT BREAKER

NSN, MFG P/N

5925013232319

NSN

5925-01-323-2319

MFG

GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL

MP320

CIRCUIT BREAKER

NSN, MFG P/N

5925013233796

NSN

5925-01-323-3796

View More Info

MP320

CIRCUIT BREAKER

NSN, MFG P/N

5925013233796

NSN

5925-01-323-3796

MFG

COOPER INDUSTRIES INC COOPER DISTRIBUTION EQUIPMENT DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY STYLE: 7C MULTIPOLE-MULTIPLE ACTUATOR TYPE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 3 CLIP AND 3 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 3 COMPRESSION AND 3 CLIP
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 6.000 MINIMUM AT 200 PCT AND 80.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

UPL-1111-7007-69

CIRCUIT BREAKER

NSN, MFG P/N

5925013234173

NSN

5925-01-323-4173

View More Info

UPL-1111-7007-69

CIRCUIT BREAKER

NSN, MFG P/N

5925013234173

NSN

5925-01-323-4173

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

BODY HEIGHT: 2.000 INCHES MAXIMUM
BODY LENGTH: 2.490 INCHES NOMINAL
BODY WIDTH: 2.250 INCHES MAXIMUM
FREQUENCY IN HERTZ: 50.0 OR 60.0 SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED STUD
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 277.0 AC SINGLE LOCATION
POLE QUANTITY: 3
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC

GJ3-A3-DU0150-03A

CIRCUIT BREAKER

NSN, MFG P/N

5925013234174

NSN

5925-01-323-4174

View More Info

GJ3-A3-DU0150-03A

CIRCUIT BREAKER

NSN, MFG P/N

5925013234174

NSN

5925-01-323-4174

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 250.0 AMPERES AC SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 3.0 AC SINGLE LOCATION
POLE QUANTITY: 3
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION

12873136

CIRCUIT BREAKER

NSN, MFG P/N

5925013235173

NSN

5925-01-323-5173

View More Info

12873136

CIRCUIT BREAKER

NSN, MFG P/N

5925013235173

NSN

5925-01-323-5173

MFG

NATIONAL MULTI PRODUCTS CO

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 7.400 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: CORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.625 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPECIAL FEATURES: UTILIZED ON GENERATOR SET 5KW,TRAILER MTD,E/I NSN6115013031484
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS

APL11-23690-1

CIRCUIT BREAKER

NSN, MFG P/N

5925013235173

NSN

5925-01-323-5173

View More Info

APL11-23690-1

CIRCUIT BREAKER

NSN, MFG P/N

5925013235173

NSN

5925-01-323-5173

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 7.400 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: CORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.625 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPECIAL FEATURES: UTILIZED ON GENERATOR SET 5KW,TRAILER MTD,E/I NSN6115013031484
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS