5925-01-407-3071

20 Products

M39019/01-318S

CIRCUIT BREAKER

NSN, MFG P/N

5925014073071

NSN

5925-01-407-3071

View More Info

M39019/01-318S

CIRCUIT BREAKER

NSN, MFG P/N

5925014073071

NSN

5925-01-407-3071

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 2A SINGLE POLE TYPE
BODY WIDTH: 0.625 INCHES MAXIMUM
BUSHING LENGTH: 0.380 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.960 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39019/01-318S
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 4.0 AMPERES AC AND 4.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC AND 500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.700 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-39019/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC AND 50.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-39019/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 81349-MIL-39019 SPECIFICATION
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

33227

CIRCUIT BREAKER

NSN, MFG P/N

5925014068604

NSN

5925-01-406-8604

View More Info

33227

CIRCUIT BREAKER

NSN, MFG P/N

5925014068604

NSN

5925-01-406-8604

MFG

ATLAS ENERGY SYSTEMS INC

33210

CIRCUIT BREAKER

NSN, MFG P/N

5925014068605

NSN

5925-01-406-8605

View More Info

33210

CIRCUIT BREAKER

NSN, MFG P/N

5925014068605

NSN

5925-01-406-8605

MFG

ATLAS ENERGY SYSTEMS INC

CVC2523-3

CIRCUIT BREAKER

NSN, MFG P/N

5925014069470

NSN

5925-01-406-9470

View More Info

CVC2523-3

CIRCUIT BREAKER

NSN, MFG P/N

5925014069470

NSN

5925-01-406-9470

MFG

VOUGHT AIRCRAFT INDUSTRIES INC.

295-111-1-62-4A-303-AH

CIRCUIT BREAKER

NSN, MFG P/N

5925014069898

NSN

5925-01-406-9898

View More Info

295-111-1-62-4A-303-AH

CIRCUIT BREAKER

NSN, MFG P/N

5925014069898

NSN

5925-01-406-9898

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 3

21811

BASE,CIRCUIT BREAKER

NSN, MFG P/N

5925014070600

NSN

5925-01-407-0600

View More Info

21811

BASE,CIRCUIT BREAKER

NSN, MFG P/N

5925014070600

NSN

5925-01-407-0600

MFG

ATLAS ENERGY SYSTEMS INC

ETN-6314

CIRCUIT BREAKER

NSN, MFG P/N

5925014071241

NSN

5925-01-407-1241

View More Info

ETN-6314

CIRCUIT BREAKER

NSN, MFG P/N

5925014071241

NSN

5925-01-407-1241

MFG

SPD ELECTRICAL SYSTEMS INC

Description

DESIGN CONTROL REFERENCE: ETN-6314
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
MANUFACTURERS CODE: 30086
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
POLE QUANTITY: 3
THE MANUFACTURERS DATA:

116200

CIRCUIT BREAKER

NSN, MFG P/N

5925014071293

NSN

5925-01-407-1293

View More Info

116200

CIRCUIT BREAKER

NSN, MFG P/N

5925014071293

NSN

5925-01-407-1293

MFG

SPD ELECTRICAL SYSTEMS INC

Description

AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 CONTROL
CASE MATERIAL: PLASTIC
FEATURES PROVIDED: CURRENT LIMITER AND HANDLE LOCK
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 225.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 100000.0 AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: SOLID STATE ALL LOCATIONS

ETN-6300

CIRCUIT BREAKER

NSN, MFG P/N

5925014071294

NSN

5925-01-407-1294

View More Info

ETN-6300

CIRCUIT BREAKER

NSN, MFG P/N

5925014071294

NSN

5925-01-407-1294

MFG

SPD ELECTRICAL SYSTEMS INC

ETN-6306

CIRCUIT BREAKER

NSN, MFG P/N

5925014071363

NSN

5925-01-407-1363

View More Info

ETN-6306

CIRCUIT BREAKER

NSN, MFG P/N

5925014071363

NSN

5925-01-407-1363

MFG

SPD ELECTRICAL SYSTEMS INC

1560-924041

CIRCUIT BREAKER

NSN, MFG P/N

5925014071796

NSN

5925-01-407-1796

View More Info

1560-924041

CIRCUIT BREAKER

NSN, MFG P/N

5925014071796

NSN

5925-01-407-1796

MFG

KONICA MINOLTA MEDICAL IMAGING U.S.A. INC. DBA KONICA MEDICAL

Description

DESIGN CONTROL REFERENCE: 1560-924041
MANUFACTURERS CODE: 4S405
SPECIAL FEATURES: FOR USE ON X-RAY FILM PROCESSOR, MDL QX-60A
THE MANUFACTURERS DATA:

LL-H37-3422

CIRCUIT BREAKER

NSN, MFG P/N

5925014071796

NSN

5925-01-407-1796

View More Info

LL-H37-3422

CIRCUIT BREAKER

NSN, MFG P/N

5925014071796

NSN

5925-01-407-1796

MFG

NAVAL MEDICAL MATERIAL SUPPORT COMMAND DETACHMENT

Description

DESIGN CONTROL REFERENCE: 1560-924041
MANUFACTURERS CODE: 4S405
SPECIAL FEATURES: FOR USE ON X-RAY FILM PROCESSOR, MDL QX-60A
THE MANUFACTURERS DATA:

JA3S-W3-DA-01-D-A

CIRCUIT BREAKER

NSN, MFG P/N

5925014072061

NSN

5925-01-407-2061

View More Info

JA3S-W3-DA-01-D-A

CIRCUIT BREAKER

NSN, MFG P/N

5925014072061

NSN

5925-01-407-2061

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

BODY HEIGHT: 39.5 MILLIMETERS NOMINAL
BODY WIDTH: 57.2 MILLIMETERS NOMINAL
III END ITEM IDENTIFICATION: ADATS (AIR DEFENCE ANTI-TANK SYSTEM), EATON CORP
POLE QUANTITY: 3

APL111125978-102

CIRCUIT BREAKER

NSN, MFG P/N

5925014072542

NSN

5925-01-407-2542

View More Info

APL111125978-102

CIRCUIT BREAKER

NSN, MFG P/N

5925014072542

NSN

5925-01-407-2542

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.530 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.015 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.060 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, THREE, AND FOUR LINKED
FREQUENCY IN HERTZ: 60.0 FIRST LOCATION 60.0 SECOND LOCATION 60.0 THIRD LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 4 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC FIRST LOCATION 40.0 AMPERES AC SECOND LOCATION 40.0 AMPERES AC THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 DC FIRST LOCATION 1000.0 AC SECOND LOCATION 1000.0 AC THIRD LOCATION 2000.0 DC FOURTH LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 8 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.645 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC FIRST LOCATION 240.0 AC SECOND LOCATION 240.0 AC THIRD LOCATION
POLE QUANTITY: 4
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 8 COMPRESSION
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 3.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

H505A001-102

CIRCUIT BREAKER

NSN, MFG P/N

5925014072542

NSN

5925-01-407-2542

View More Info

H505A001-102

CIRCUIT BREAKER

NSN, MFG P/N

5925014072542

NSN

5925-01-407-2542

MFG

BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION I

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.530 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.015 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.060 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, THREE, AND FOUR LINKED
FREQUENCY IN HERTZ: 60.0 FIRST LOCATION 60.0 SECOND LOCATION 60.0 THIRD LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 4 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC FIRST LOCATION 40.0 AMPERES AC SECOND LOCATION 40.0 AMPERES AC THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 DC FIRST LOCATION 1000.0 AC SECOND LOCATION 1000.0 AC THIRD LOCATION 2000.0 DC FOURTH LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 8 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.645 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC FIRST LOCATION 240.0 AC SECOND LOCATION 240.0 AC THIRD LOCATION
POLE QUANTITY: 4
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 8 COMPRESSION
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 3.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

APL111125978-103

CIRCUIT BREAKER

NSN, MFG P/N

5925014072543

NSN

5925-01-407-2543

View More Info

APL111125978-103

CIRCUIT BREAKER

NSN, MFG P/N

5925014072543

NSN

5925-01-407-2543

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.530 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.015 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.060 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, THREE, AND FOUR LINKED
FREQUENCY IN HERTZ: 60.0 FIRST LOCATION 60.0 SECOND LOCATION 60.0 THIRD LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 4 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC FIRST LOCATION 30.0 AMPERES AC SECOND LOCATION 30.0 AMPERES AC THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC FIRST LOCATION 1000.0 AC SECOND LOCATION 1000.0 AC THIRD LOCATION 2000.0 DC FOURTH LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 8 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.645 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC FIRST LOCATION 240.0 AC SECOND LOCATION 240.0 AC THIRD LOCATION 5.0 DC FOURTH LOCATION
POLE QUANTITY: 4
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 8 COMPRESSION
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 3.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 1256.0 ALL LOCATIONS

H505A001-103

CIRCUIT BREAKER

NSN, MFG P/N

5925014072543

NSN

5925-01-407-2543

View More Info

H505A001-103

CIRCUIT BREAKER

NSN, MFG P/N

5925014072543

NSN

5925-01-407-2543

MFG

BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION I

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.530 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.015 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.060 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, THREE, AND FOUR LINKED
FREQUENCY IN HERTZ: 60.0 FIRST LOCATION 60.0 SECOND LOCATION 60.0 THIRD LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 4 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC FIRST LOCATION 30.0 AMPERES AC SECOND LOCATION 30.0 AMPERES AC THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC FIRST LOCATION 1000.0 AC SECOND LOCATION 1000.0 AC THIRD LOCATION 2000.0 DC FOURTH LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 8 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.645 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC FIRST LOCATION 240.0 AC SECOND LOCATION 240.0 AC THIRD LOCATION 5.0 DC FOURTH LOCATION
POLE QUANTITY: 4
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 8 COMPRESSION
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 3.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 1256.0 ALL LOCATIONS

APL111125978-101

CIRCUIT BREAKER

NSN, MFG P/N

5925014072545

NSN

5925-01-407-2545

View More Info

APL111125978-101

CIRCUIT BREAKER

NSN, MFG P/N

5925014072545

NSN

5925-01-407-2545

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.530 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.015 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.060 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, THREE, AND FOUR LINKED
FREQUENCY IN HERTZ: 60.0 FIRST LOCATION 60.0 SECOND LOCATION 60.0 THIRD LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 4 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES AC FIRST LOCATION 50.0 AMPERES AC SECOND LOCATION 50.0 AMPERES AC THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC FIRST LOCATION 1000.0 AC SECOND LOCATION 1000.0 AC THIRD LOCATION 2000.0 DC FOURTH LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 8 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.645 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC FIRST LOCATION 240.0 AC SECOND LOCATION 240.0 AC THIRD LOCATION 5.0 DC FOURTH LOCATION
POLE QUANTITY: 4
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 8 COMPRESSION
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 3.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

H505A001-101

CIRCUIT BREAKER

NSN, MFG P/N

5925014072545

NSN

5925-01-407-2545

View More Info

H505A001-101

CIRCUIT BREAKER

NSN, MFG P/N

5925014072545

NSN

5925-01-407-2545

MFG

BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION I

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.530 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.015 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.060 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, THREE, AND FOUR LINKED
FREQUENCY IN HERTZ: 60.0 FIRST LOCATION 60.0 SECOND LOCATION 60.0 THIRD LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 4 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES AC FIRST LOCATION 50.0 AMPERES AC SECOND LOCATION 50.0 AMPERES AC THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC FIRST LOCATION 1000.0 AC SECOND LOCATION 1000.0 AC THIRD LOCATION 2000.0 DC FOURTH LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 8 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.645 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC FIRST LOCATION 240.0 AC SECOND LOCATION 240.0 AC THIRD LOCATION 5.0 DC FOURTH LOCATION
POLE QUANTITY: 4
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 8 COMPRESSION
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 3.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

AP-17-1-51-203

CIRCUIT BREAKER

NSN, MFG P/N

5925014072549

NSN

5925-01-407-2549

View More Info

AP-17-1-51-203

CIRCUIT BREAKER

NSN, MFG P/N

5925014072549

NSN

5925-01-407-2549

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY LENGTH: 1.500 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.250 INCHES MAXIMUM
BUSHING LENGTH: 0.380 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 500.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.780 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 TAB W/SCREW
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.090 MINIMUM AT 200 PCT AND 60.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS