Explore Products

My Quote Request

No products added yet

5925-01-424-2554

20 Products

GFP25C15M

INTERRUPTER,GROUND FAULT

NSN, MFG P/N

5925014242554

NSN

5925-01-424-2554

View More Info

GFP25C15M

INTERRUPTER,GROUND FAULT

NSN, MFG P/N

5925014242554

NSN

5925-01-424-2554

MFG

HUBBELL INC WIRING DEVICE DIV

Description

GENERAL CHARACTERISTICS ITEM DESCRIPTION: 25 FT. LG.; 15 A, 120 VOLTS

12422440-004

CIRCUIT BREAKER

NSN, MFG P/N

5925014237429

NSN

5925-01-423-7429

View More Info

12422440-004

CIRCUIT BREAKER

NSN, MFG P/N

5925014237429

NSN

5925-01-423-7429

MFG

BAE SYSTEMS TACTICAL VEHICLE SYSTEMS LP

13039136

CIRCUIT BREAKER

NSN, MFG P/N

5925014237429

NSN

5925-01-423-7429

View More Info

13039136

CIRCUIT BREAKER

NSN, MFG P/N

5925014237429

NSN

5925-01-423-7429

MFG

CHAMPION ROAD MACHINERY INC PRO-PAV DIV

VB3-M20-F33

CIRCUIT BREAKER

NSN, MFG P/N

5925014237429

NSN

5925-01-423-7429

View More Info

VB3-M20-F33

CIRCUIT BREAKER

NSN, MFG P/N

5925014237429

NSN

5925-01-423-7429

MFG

SNAP ACTION INC

AM3-A3-A-0020-03-E

CIRCUIT BREAKER

NSN, MFG P/N

5925014237434

NSN

5925-01-423-7434

View More Info

AM3-A3-A-0020-03-E

CIRCUIT BREAKER

NSN, MFG P/N

5925014237434

NSN

5925-01-423-7434

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 3

NB221025

CIRCUIT BREAKER

NSN, MFG P/N

5925014237454

NSN

5925-01-423-7454

View More Info

NB221025

CIRCUIT BREAKER

NSN, MFG P/N

5925014237454

NSN

5925-01-423-7454

MFG

AMERICAN CIRCUIT BREAKER CORP

Description

BODY STYLE: 10A SINGLE POLE TYPE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES AC ALL LOCATIONS
POLE QUANTITY: 2

AA-662-4

CIRCUIT BREAKER

NSN, MFG P/N

5925014237455

NSN

5925-01-423-7455

View More Info

AA-662-4

CIRCUIT BREAKER

NSN, MFG P/N

5925014237455

NSN

5925-01-423-7455

MFG

INSTITUTE OF MANAGEMENT INSTRUCTION INC DBA INTL MANAGEMENT INSTITUTE

QOU210

CIRCUIT BREAKER

NSN, MFG P/N

5925014237803

NSN

5925-01-423-7803

View More Info

QOU210

CIRCUIT BREAKER

NSN, MFG P/N

5925014237803

NSN

5925-01-423-7803

MFG

SCHNEIDER ELECTRIC USA INC.

Description

ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: QOU210
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III END ITEM IDENTIFICATION: CONTROL, FIRE P/N TX-100 ONBOARD 175 FT WLM COAST GUARD VESSELS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUFACTURERS CODE: 56365
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC AND 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
THE MANUFACTURERS DATA:
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS

1342AS146

CIRCUIT BREAKER BOX SUBASSEMBLY

NSN, MFG P/N

5925014241407

NSN

5925-01-424-1407

View More Info

1342AS146

CIRCUIT BREAKER BOX SUBASSEMBLY

NSN, MFG P/N

5925014241407

NSN

5925-01-424-1407

MFG

NAVAL AIR SYSTEMS COMMAND

Description

DESIGN CONTROL REFERENCE: 1342AS146
III END ITEM IDENTIFICATION: AIRCRAFT MODEL A-6E (PECULIAR)
MANUFACTURERS CODE: 30003
THE MANUFACTURERS DATA:

M39019/02-249S

CIRCUIT BREAKER

NSN, MFG P/N

5925014241709

NSN

5925-01-424-1709

View More Info

M39019/02-249S

CIRCUIT BREAKER

NSN, MFG P/N

5925014241709

NSN

5925-01-424-1709

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.281 INCHES MAXIMUM
BUSHING LENGTH: 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.610 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39019/02-249S
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC ALL LOCATIONS
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.828 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-39019/3
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M39019/03 GOVERNMENT SPECIFICATION
TEST DATA DOCUMENT: 81349-MIL-C-39019 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 ALL LOCATIONS

281218

CIRCUIT BREAKER

NSN, MFG P/N

5925014241710

NSN

5925-01-424-1710

View More Info

281218

CIRCUIT BREAKER

NSN, MFG P/N

5925014241710

NSN

5925-01-424-1710

MFG

HENLEY MARINE INC SAN DIEGO OPNS

Description

BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 0.500 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.200 MINIMUM AT 200 PCT AND 7.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

AP-12-1RC-25581-1

CIRCUIT BREAKER

NSN, MFG P/N

5925014241710

NSN

5925-01-424-1710

View More Info

AP-12-1RC-25581-1

CIRCUIT BREAKER

NSN, MFG P/N

5925014241710

NSN

5925-01-424-1710

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 0.500 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.200 MINIMUM AT 200 PCT AND 7.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

6510-002-5

CIRCUIT BREAKER

NSN, MFG P/N

5925014242425

NSN

5925-01-424-2425

View More Info

6510-002-5

CIRCUIT BREAKER

NSN, MFG P/N

5925014242425

NSN

5925-01-424-2425

MFG

EATON CORPORATION DBA FLUID POWER DIV DIV POWER AND LOAD MANAGEMENT SYSTEMS USE CAGE CODE 81640 FOR CATALOGING.

Description

BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.200 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.530 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M83383/02-01
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.940 INCHES NOMINAL
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3600.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 4.260 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-83383/2
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC AND 115.0 AC SINGLE LOCATION
OVERALL LENGTH: 3.250 INCHES MAXIMUM
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-83383 GOVERNMENT SPECIFICATION AND 81349-M83383/02 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-83383 SPECIFICATION AND 81349-M83383/02 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 7.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT AND 1.200 MINIMUM AT 400 PCT AND 6.400 MAXIMUM AT 400 PCT AND 0.300 MINIMUM AT 1000 PCT AND 1.200 MAXIMUM AT 1000 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: -54.0 DEG CELSIUS MINIMUM AND 71.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 200.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.172 INCHES NOMINAL

M83383/02-01

CIRCUIT BREAKER

NSN, MFG P/N

5925014242425

NSN

5925-01-424-2425

View More Info

M83383/02-01

CIRCUIT BREAKER

NSN, MFG P/N

5925014242425

NSN

5925-01-424-2425

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.200 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.530 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M83383/02-01
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.940 INCHES NOMINAL
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3600.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 4.260 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-83383/2
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC AND 115.0 AC SINGLE LOCATION
OVERALL LENGTH: 3.250 INCHES MAXIMUM
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-83383 GOVERNMENT SPECIFICATION AND 81349-M83383/02 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-83383 SPECIFICATION AND 81349-M83383/02 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 7.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT AND 1.200 MINIMUM AT 400 PCT AND 6.400 MAXIMUM AT 400 PCT AND 0.300 MINIMUM AT 1000 PCT AND 1.200 MAXIMUM AT 1000 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: -54.0 DEG CELSIUS MINIMUM AND 71.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 200.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.172 INCHES NOMINAL

M39019/05-321S

CIRCUIT BREAKER

NSN, MFG P/N

5925014242443

NSN

5925-01-424-2443

View More Info

M39019/05-321S

CIRCUIT BREAKER

NSN, MFG P/N

5925014242443

NSN

5925-01-424-2443

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.937 INCHES MAXIMUM
BUSHING LENGTH: 0.350 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.937 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39019/05-321S
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FEATURES PROVIDED: HIGH INRUSH PROTECTION
FREQUENCY IN HERTZ: 60.0 OR 400.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.950 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-39019
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC AND 240.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-39019 GOVERNMENT SPECIFICATION AND 39019/05 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 6 SCREW
TEST DATA DOCUMENT: 81349-MIL-C-39019 SPECIFICATION AND 81349-M39019/05 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.100 MINIMUM AT 800 PCT AND 500.000 MAXIMUM AT 135 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 ALL LOCATIONS

203-22-1-66F-103-4-1-1-A

CIRCUIT BREAKER

NSN, MFG P/N

5925014242460

NSN

5925-01-424-2460

View More Info

203-22-1-66F-103-4-1-1-A

CIRCUIT BREAKER

NSN, MFG P/N

5925014242460

NSN

5925-01-424-2460

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP W/SEPARATE RESET
BODY LENGTH: 1.610 INCHES MAXIMUM
BODY STYLE: 3B MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.320 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 OR 400.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC AND 1000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 2 CLIP
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.770 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC ALL LOCATIONS
POLE QUANTITY: 2
TERMINAL TYPE AND QUANTITY: 2 COMPRESSION
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS

995202-031

CIRCUIT BREAKER

NSN, MFG P/N

5925014242460

NSN

5925-01-424-2460

View More Info

995202-031

CIRCUIT BREAKER

NSN, MFG P/N

5925014242460

NSN

5925-01-424-2460

MFG

BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION I

Description

ACTUATOR FUNCTION: TRIP W/SEPARATE RESET
BODY LENGTH: 1.610 INCHES MAXIMUM
BODY STYLE: 3B MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.320 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 OR 400.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC AND 1000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 2 CLIP
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.770 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC ALL LOCATIONS
POLE QUANTITY: 2
TERMINAL TYPE AND QUANTITY: 2 COMPRESSION
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS

41-11-P10-F40-RS-19F5

CIRCUIT BREAKER

NSN, MFG P/N

5925014242500

NSN

5925-01-424-2500

View More Info

41-11-P10-F40-RS-19F5

CIRCUIT BREAKER

NSN, MFG P/N

5925014242500

NSN

5925-01-424-2500

MFG

OAKLAND INDUSTRIES LTD DBA E-T-A CIRCUIT BREAKERS

Description

FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES DC SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1

11453

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925014242503

NSN

5925-01-424-2503

View More Info

11453

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925014242503

NSN

5925-01-424-2503

MFG

ROYAL WHOLESALE ELECTRIC

88-183021-1

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925014242503

NSN

5925-01-424-2503

View More Info

88-183021-1

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925014242503

NSN

5925-01-424-2503

MFG

NORTHROP GRUMMAN SPACE & MISSION SYSTEMS CORP. DIV INTELLIGENCE SYSTEMS DIVISION/ESL