My Quote Request
5925-01-424-2554
20 Products
GFP25C15M
INTERRUPTER,GROUND FAULT
NSN, MFG P/N
5925014242554
NSN
5925-01-424-2554
MFG
HUBBELL INC WIRING DEVICE DIV
Description
GENERAL CHARACTERISTICS ITEM DESCRIPTION: 25 FT. LG.; 15 A, 120 VOLTS
Related Searches:
12422440-004
CIRCUIT BREAKER
NSN, MFG P/N
5925014237429
NSN
5925-01-423-7429
MFG
BAE SYSTEMS TACTICAL VEHICLE SYSTEMS LP
Description
CIRCUIT BREAKER
Related Searches:
13039136
CIRCUIT BREAKER
NSN, MFG P/N
5925014237429
NSN
5925-01-423-7429
MFG
CHAMPION ROAD MACHINERY INC PRO-PAV DIV
Description
CIRCUIT BREAKER
Related Searches:
VB3-M20-F33
CIRCUIT BREAKER
NSN, MFG P/N
5925014237429
NSN
5925-01-423-7429
MFG
SNAP ACTION INC
Description
CIRCUIT BREAKER
Related Searches:
AM3-A3-A-0020-03-E
CIRCUIT BREAKER
NSN, MFG P/N
5925014237434
NSN
5925-01-423-7434
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 3
Related Searches:
NB221025
CIRCUIT BREAKER
NSN, MFG P/N
5925014237454
NSN
5925-01-423-7454
MFG
AMERICAN CIRCUIT BREAKER CORP
Description
BODY STYLE: 10A SINGLE POLE TYPE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES AC ALL LOCATIONS
POLE QUANTITY: 2
Related Searches:
AA-662-4
CIRCUIT BREAKER
NSN, MFG P/N
5925014237455
NSN
5925-01-423-7455
MFG
INSTITUTE OF MANAGEMENT INSTRUCTION INC DBA INTL MANAGEMENT INSTITUTE
Description
CIRCUIT BREAKER
Related Searches:
QOU210
CIRCUIT BREAKER
NSN, MFG P/N
5925014237803
NSN
5925-01-423-7803
MFG
SCHNEIDER ELECTRIC USA INC.
Description
ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: QOU210
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III END ITEM IDENTIFICATION: CONTROL, FIRE P/N TX-100 ONBOARD 175 FT WLM COAST GUARD VESSELS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUFACTURERS CODE: 56365
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC AND 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
THE MANUFACTURERS DATA:
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
Related Searches:
1342AS146
CIRCUIT BREAKER BOX SUBASSEMBLY
NSN, MFG P/N
5925014241407
NSN
5925-01-424-1407
1342AS146
CIRCUIT BREAKER BOX SUBASSEMBLY
NSN, MFG P/N
5925014241407
NSN
5925-01-424-1407
MFG
NAVAL AIR SYSTEMS COMMAND
Description
DESIGN CONTROL REFERENCE: 1342AS146
III END ITEM IDENTIFICATION: AIRCRAFT MODEL A-6E (PECULIAR)
MANUFACTURERS CODE: 30003
THE MANUFACTURERS DATA:
Related Searches:
M39019/02-249S
CIRCUIT BREAKER
NSN, MFG P/N
5925014241709
NSN
5925-01-424-1709
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.281 INCHES MAXIMUM
BUSHING LENGTH: 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.610 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39019/02-249S
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC ALL LOCATIONS
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.828 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-39019/3
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M39019/03 GOVERNMENT SPECIFICATION
TEST DATA DOCUMENT: 81349-MIL-C-39019 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 ALL LOCATIONS
Related Searches:
281218
CIRCUIT BREAKER
NSN, MFG P/N
5925014241710
NSN
5925-01-424-1710
MFG
HENLEY MARINE INC SAN DIEGO OPNS
Description
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 0.500 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.200 MINIMUM AT 200 PCT AND 7.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
AP-12-1RC-25581-1
CIRCUIT BREAKER
NSN, MFG P/N
5925014241710
NSN
5925-01-424-1710
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 0.500 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.200 MINIMUM AT 200 PCT AND 7.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
6510-002-5
CIRCUIT BREAKER
NSN, MFG P/N
5925014242425
NSN
5925-01-424-2425
MFG
EATON CORPORATION DBA FLUID POWER DIV DIV POWER AND LOAD MANAGEMENT SYSTEMS USE CAGE CODE 81640 FOR CATALOGING.
Description
BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.200 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.530 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M83383/02-01
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.940 INCHES NOMINAL
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3600.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 4.260 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-83383/2
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC AND 115.0 AC SINGLE LOCATION
OVERALL LENGTH: 3.250 INCHES MAXIMUM
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-83383 GOVERNMENT SPECIFICATION AND 81349-M83383/02 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-83383 SPECIFICATION AND 81349-M83383/02 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 7.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT AND 1.200 MINIMUM AT 400 PCT AND 6.400 MAXIMUM AT 400 PCT AND 0.300 MINIMUM AT 1000 PCT AND 1.200 MAXIMUM AT 1000 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: -54.0 DEG CELSIUS MINIMUM AND 71.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 200.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.172 INCHES NOMINAL
Related Searches:
M83383/02-01
CIRCUIT BREAKER
NSN, MFG P/N
5925014242425
NSN
5925-01-424-2425
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.200 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.530 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M83383/02-01
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.940 INCHES NOMINAL
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3600.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 4.260 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-83383/2
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC AND 115.0 AC SINGLE LOCATION
OVERALL LENGTH: 3.250 INCHES MAXIMUM
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-83383 GOVERNMENT SPECIFICATION AND 81349-M83383/02 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-83383 SPECIFICATION AND 81349-M83383/02 SPECIFICATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 7.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT AND 1.200 MINIMUM AT 400 PCT AND 6.400 MAXIMUM AT 400 PCT AND 0.300 MINIMUM AT 1000 PCT AND 1.200 MAXIMUM AT 1000 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: -54.0 DEG CELSIUS MINIMUM AND 71.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 200.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.172 INCHES NOMINAL
Related Searches:
M39019/05-321S
CIRCUIT BREAKER
NSN, MFG P/N
5925014242443
NSN
5925-01-424-2443
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.937 INCHES MAXIMUM
BUSHING LENGTH: 0.350 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.937 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39019/05-321S
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FEATURES PROVIDED: HIGH INRUSH PROTECTION
FREQUENCY IN HERTZ: 60.0 OR 400.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.950 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-39019
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC AND 240.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-39019 GOVERNMENT SPECIFICATION AND 39019/05 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 6 SCREW
TEST DATA DOCUMENT: 81349-MIL-C-39019 SPECIFICATION AND 81349-M39019/05 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.100 MINIMUM AT 800 PCT AND 500.000 MAXIMUM AT 135 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 ALL LOCATIONS
Related Searches:
203-22-1-66F-103-4-1-1-A
CIRCUIT BREAKER
NSN, MFG P/N
5925014242460
NSN
5925-01-424-2460
203-22-1-66F-103-4-1-1-A
CIRCUIT BREAKER
NSN, MFG P/N
5925014242460
NSN
5925-01-424-2460
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
ACTUATOR FUNCTION: TRIP W/SEPARATE RESET
BODY LENGTH: 1.610 INCHES MAXIMUM
BODY STYLE: 3B MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.320 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 OR 400.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC AND 1000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 2 CLIP
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.770 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC ALL LOCATIONS
POLE QUANTITY: 2
TERMINAL TYPE AND QUANTITY: 2 COMPRESSION
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
Related Searches:
995202-031
CIRCUIT BREAKER
NSN, MFG P/N
5925014242460
NSN
5925-01-424-2460
MFG
BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION I
Description
ACTUATOR FUNCTION: TRIP W/SEPARATE RESET
BODY LENGTH: 1.610 INCHES MAXIMUM
BODY STYLE: 3B MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.320 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 OR 400.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC AND 1000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 2 CLIP
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.770 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC ALL LOCATIONS
POLE QUANTITY: 2
TERMINAL TYPE AND QUANTITY: 2 COMPRESSION
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
Related Searches:
41-11-P10-F40-RS-19F5
CIRCUIT BREAKER
NSN, MFG P/N
5925014242500
NSN
5925-01-424-2500
41-11-P10-F40-RS-19F5
CIRCUIT BREAKER
NSN, MFG P/N
5925014242500
NSN
5925-01-424-2500
MFG
OAKLAND INDUSTRIES LTD DBA E-T-A CIRCUIT BREAKERS
Description
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES DC SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
Related Searches:
11453
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925014242503
NSN
5925-01-424-2503
MFG
ROYAL WHOLESALE ELECTRIC
Description
CIRCUIT BREAKER BOX
Related Searches:
88-183021-1
CIRCUIT BREAKER BOX
NSN, MFG P/N
5925014242503
NSN
5925-01-424-2503
MFG
NORTHROP GRUMMAN SPACE & MISSION SYSTEMS CORP. DIV INTELLIGENCE SYSTEMS DIVISION/ESL
Description
CIRCUIT BREAKER BOX