Explore Products

My Quote Request

No products added yet

5925-01-493-1727

20 Products

ASC1558973

CIRCUIT BREAKER

NSN, MFG P/N

5925014931727

NSN

5925-01-493-1727

View More Info

ASC1558973

CIRCUIT BREAKER

NSN, MFG P/N

5925014931727

NSN

5925-01-493-1727

MFG

ASC PTY LTD

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: MOISTURE RESISTANT AND SALT SPRAY PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 2.5 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.475 INCHES NOMINAL
NOMINAL THREAD SIZE: 3.0 MILLIMETERS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 65.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD PITCH IN MILLIMETERS: 0.50
THREAD SERIES DESIGNATOR: ISO S
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.700 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS

15-825N47

CIRCUIT BREAKER

NSN, MFG P/N

5925014924177

NSN

5925-01-492-4177

View More Info

15-825N47

CIRCUIT BREAKER

NSN, MFG P/N

5925014924177

NSN

5925-01-492-4177

MFG

WESCO DISTRIBUTION INC.

Description

III PART NAME ASSIGNED BY CONTROLLING AGENCY: CIRCUIT BREAKER 34E

S456D988G60

CIRCUIT BREAKER

NSN, MFG P/N

5925014924178

NSN

5925-01-492-4178

View More Info

S456D988G60

CIRCUIT BREAKER

NSN, MFG P/N

5925014924178

NSN

5925-01-492-4178

MFG

WESCO DISTRIBUTION INC.

Description

III PART NAME ASSIGNED BY CONTROLLING AGENCY: CIRCUIT BREAKER JA

S451D856G06

CIRCUIT BREAKER

NSN, MFG P/N

5925014924180

NSN

5925-01-492-4180

View More Info

S451D856G06

CIRCUIT BREAKER

NSN, MFG P/N

5925014924180

NSN

5925-01-492-4180

MFG

WESCO DISTRIBUTION INC.

Description

III PART NAME ASSIGNED BY CONTROLLING AGENCY: CIRCUIT BREAKER NQB

S1400244

CIRCUIT BREAKER

NSN, MFG P/N

5925014924181

NSN

5925-01-492-4181

View More Info

S1400244

CIRCUIT BREAKER

NSN, MFG P/N

5925014924181

NSN

5925-01-492-4181

MFG

WESCO DISTRIBUTION INC.

Description

III PART NAME ASSIGNED BY CONTROLLING AGENCY: CIRCUIT BREAKER AQB

S451D856G04

CIRCUIT BREAKER

NSN, MFG P/N

5925014924182

NSN

5925-01-492-4182

View More Info

S451D856G04

CIRCUIT BREAKER

NSN, MFG P/N

5925014924182

NSN

5925-01-492-4182

MFG

WESCO DISTRIBUTION INC.

Description

III PART NAME ASSIGNED BY CONTROLLING AGENCY: CIRCUIT BREAKER NQB

S451D856G02

CIRCUIT BREAKER

NSN, MFG P/N

5925014924183

NSN

5925-01-492-4183

View More Info

S451D856G02

CIRCUIT BREAKER

NSN, MFG P/N

5925014924183

NSN

5925-01-492-4183

MFG

WESCO DISTRIBUTION INC.

Description

III PART NAME ASSIGNED BY CONTROLLING AGENCY: CIRCUIT BREAKER NQB

JA3070/1A-1B

CIRCUIT BREAKER

NSN, MFG P/N

5925014924184

NSN

5925-01-492-4184

View More Info

JA3070/1A-1B

CIRCUIT BREAKER

NSN, MFG P/N

5925014924184

NSN

5925-01-492-4184

MFG

WESCO DISTRIBUTION INC.

Description

III PART NAME ASSIGNED BY CONTROLLING AGENCY: CIRCUIT BREAKER JA3

35E-7916

CIRCUIT BREAKER

NSN, MFG P/N

5925014924188

NSN

5925-01-492-4188

View More Info

35E-7916

CIRCUIT BREAKER

NSN, MFG P/N

5925014924188

NSN

5925-01-492-4188

MFG

WESCO DISTRIBUTION INC.

Description

III PART NAME ASSIGNED BY CONTROLLING AGENCY: CIRCUIT BREAKER 35E

106995

CIRCUIT BREAKER

NSN, MFG P/N

5925014924782

NSN

5925-01-492-4782

View More Info

106995

CIRCUIT BREAKER

NSN, MFG P/N

5925014924782

NSN

5925-01-492-4782

MFG

CHAMPION INDUSTRIES INC .

Description

III END ITEM IDENTIFICATION: DISHWASHER
SPECIAL FEATURES: 5 AMPS

APL-11-1-52-202A

CIRCUIT BREAKER

NSN, MFG P/N

5925014927034

NSN

5925-01-492-7034

View More Info

APL-11-1-52-202A

CIRCUIT BREAKER

NSN, MFG P/N

5925014927034

NSN

5925-01-492-7034

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.500 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 27.400 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.475 INCHES NOMINAL
NOMINAL THREAD SIZE: 3.0 MILLIMETERS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 65.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD PITCH IN MILLIMETERS: 0.50
THREAD SERIES DESIGNATOR: ISO S
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.700 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS

ASC1516942

CIRCUIT BREAKER

NSN, MFG P/N

5925014927034

NSN

5925-01-492-7034

View More Info

ASC1516942

CIRCUIT BREAKER

NSN, MFG P/N

5925014927034

NSN

5925-01-492-7034

MFG

ASC PTY LTD

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.500 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 27.400 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.475 INCHES NOMINAL
NOMINAL THREAD SIZE: 3.0 MILLIMETERS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 65.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD PITCH IN MILLIMETERS: 0.50
THREAD SERIES DESIGNATOR: ISO S
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.700 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS

2566-931

CIRCUIT BREAKER

NSN, MFG P/N

5925014927565

NSN

5925-01-492-7565

View More Info

2566-931

CIRCUIT BREAKER

NSN, MFG P/N

5925014927565

NSN

5925-01-492-7565

MFG

RELIANCE COMM/TEC CORP LORAIN PRODUCTS DIV

Description

III END ITEM IDENTIFICATION: DEFINITY; WEAPON SYSTEM-COMMUNICATIONS & DATA SYSTEMS
SPECIAL FEATURES: 30 AMP; ELECTRICAL OR MECHANICAL TRIP; BOLT-IN

2566-943

CIRCUIT BREAKER

NSN, MFG P/N

5925014927566

NSN

5925-01-492-7566

View More Info

2566-943

CIRCUIT BREAKER

NSN, MFG P/N

5925014927566

NSN

5925-01-492-7566

MFG

RELIANCE COMM/TEC CORP LORAIN PRODUCTS DIV

Description

III END ITEM IDENTIFICATION: DEFINITY; WEAPON SYSTEM-COMMUNICATIONS & DATA SYSTEMS
SPECIAL FEATURES: 50 AMP; ELECTRICAL OR MECHANICAL TRIP; BOLT-IN

295-111-1REC2-4851-5

CIRCUIT BREAKER

NSN, MFG P/N

5925014928354

NSN

5925-01-492-8354

View More Info

295-111-1REC2-4851-5

CIRCUIT BREAKER

NSN, MFG P/N

5925014928354

NSN

5925-01-492-8354

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

III PART NAME ASSIGNED BY CONTROLLING AGENCY: MAGNETIC CIRCUIT BREAKER

ACB-902R-SPEC CD746732

CIRCUIT BREAKER

NSN, MFG P/N

5925014929847

NSN

5925-01-492-9847

View More Info

ACB-902R-SPEC CD746732

CIRCUIT BREAKER

NSN, MFG P/N

5925014929847

NSN

5925-01-492-9847

MFG

SPD ELECTRICAL SYSTEMS INC

Description

BODY LENGTH: 18.938 INCHES NOMINAL
BODY STYLE: 19B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 10.250 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MOUNTING SURFACE TO TERMINAL END DISTANCE: 13.813 INCHES NOMINAL
POLE QUANTITY: 3
SPECIAL FEATURES: OPERATION: ELECTRICAL(120 VAC) O R MANUAL; OVERLOAD DEVICES: TWO ELECT TROMECHANICAL OVERLOADS; INTERRUPTING RATING: 50KA RMS SYM; SHORT TIME WITHSTAND RATING:25KA FOR ONE HALF SECOND

APL-11-1-62-353A

CIRCUIT BREAKER

NSN, MFG P/N

5925014931693

NSN

5925-01-493-1693

View More Info

APL-11-1-62-353A

CIRCUIT BREAKER

NSN, MFG P/N

5925014931693

NSN

5925-01-493-1693

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: MOISTURE RESISTANT AND SALT SPRAY PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 35.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.475 INCHES NOMINAL
NOMINAL THREAD SIZE: 3.0 MILLIMETERS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD PITCH IN MILLIMETERS: 0.50
THREAD SERIES DESIGNATOR: ISO S
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 MINIMUM AT 200 PCT AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS

ASC1559035

CIRCUIT BREAKER

NSN, MFG P/N

5925014931693

NSN

5925-01-493-1693

View More Info

ASC1559035

CIRCUIT BREAKER

NSN, MFG P/N

5925014931693

NSN

5925-01-493-1693

MFG

ASC PTY LTD

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: MOISTURE RESISTANT AND SALT SPRAY PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 35.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.475 INCHES NOMINAL
NOMINAL THREAD SIZE: 3.0 MILLIMETERS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD PITCH IN MILLIMETERS: 0.50
THREAD SERIES DESIGNATOR: ISO S
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 MINIMUM AT 200 PCT AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS

APL-111-1-66-102

CIRCUIT BREAKER

NSN, MFG P/N

5925014931723

NSN

5925-01-493-1723

View More Info

APL-111-1-66-102

CIRCUIT BREAKER

NSN, MFG P/N

5925014931723

NSN

5925-01-493-1723

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.265 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.735 INCHES NOMINAL AND 0.765 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: MOISTURE RESISTANT AND SALT SPRAY PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.475 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS

APL-11-1-52-252A

CIRCUIT BREAKER

NSN, MFG P/N

5925014931727

NSN

5925-01-493-1727

View More Info

APL-11-1-52-252A

CIRCUIT BREAKER

NSN, MFG P/N

5925014931727

NSN

5925-01-493-1727

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: MOISTURE RESISTANT AND SALT SPRAY PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 2.5 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.475 INCHES NOMINAL
NOMINAL THREAD SIZE: 3.0 MILLIMETERS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 65.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD PITCH IN MILLIMETERS: 0.50
THREAD SERIES DESIGNATOR: ISO S
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.700 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 115.0 ALL LOCATIONS