Explore Products

My Quote Request

No products added yet

6525-01-012-9379

20 Products

S21018

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129379

NSN

6525-01-012-9379

View More Info

S21018

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129379

NSN

6525-01-012-9379

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 140000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959114
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.5 MM SQ; 1.5 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS TUNGSTEN 125 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 180.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: TUNGSTEN
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 125.0 KILOVOLTS

652500C959113

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129380

NSN

6525-01-012-9380

View More Info

652500C959113

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129380

NSN

6525-01-012-9380

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 140000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959113
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.0 MM SQ; 2.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL @BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS TUNGSTEN 150 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 180.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: TUNGSTEN
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 125.0 KILOVOLTS

S20918

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129380

NSN

6525-01-012-9380

View More Info

S20918

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129380

NSN

6525-01-012-9380

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 140000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959113
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.0 MM SQ; 2.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL @BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS TUNGSTEN 150 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 180.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: TUNGSTEN
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 125.0 KILOVOLTS

652500C959118

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129381

NSN

6525-01-012-9381

View More Info

652500C959118

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129381

NSN

6525-01-012-9381

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 140000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959118
FEATURES PROVIDED: EXPLOSION PROOF
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.5 MM SQ; 1.5 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS TUNGSTEN 125 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 105.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: TUNGSTEN
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 125.0 KILOVOLTS

S21019

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129381

NSN

6525-01-012-9381

View More Info

S21019

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129381

NSN

6525-01-012-9381

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 140000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959118
FEATURES PROVIDED: EXPLOSION PROOF
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.5 MM SQ; 1.5 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS TUNGSTEN 125 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 105.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: TUNGSTEN
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 125.0 KILOVOLTS

652500C959115

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129382

NSN

6525-01-012-9382

View More Info

652500C959115

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129382

NSN

6525-01-012-9382

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 140000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959115
FEATURES PROVIDED: EXPLOSION PROOF
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.0 MM SQ; 2.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS TUNGSTEN 125 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 105.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: TUNGSTEN
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 125.0 KILOVOLTS

S21919

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129382

NSN

6525-01-012-9382

View More Info

S21919

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129382

NSN

6525-01-012-9382

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 140000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959115
FEATURES PROVIDED: EXPLOSION PROOF
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.0 MM SQ; 2.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS TUNGSTEN 125 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 105.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: TUNGSTEN
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 125.0 KILOVOLTS

652500C959108

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129383

NSN

6525-01-012-9383

View More Info

652500C959108

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129383

NSN

6525-01-012-9383

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959108
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.6 MM SQ; 2.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MED X-RAY APPAR TUNGSTEN-RHENIUM ALLOY 150 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 270.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

S23830

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129383

NSN

6525-01-012-9383

View More Info

S23830

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129383

NSN

6525-01-012-9383

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959108
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.6 MM SQ; 2.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MED X-RAY APPAR TUNGSTEN-RHENIUM ALLOY 150 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 270.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

652500G959040

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129384

NSN

6525-01-012-9384

View More Info

652500G959040

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129384

NSN

6525-01-012-9384

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 140000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500G959040
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.0 MM SQ; 2.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS TUNGSTEN 130 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 180.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: TUNGSTEN
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 130.0 KILOVOLTS

S20929

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129384

NSN

6525-01-012-9384

View More Info

S20929

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010129384

NSN

6525-01-012-9384

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 140000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500G959040
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.0 MM SQ; 2.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS TUNGSTEN 130 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 180.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: TUNGSTEN
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 130.0 KILOVOLTS

146-4890

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129686

NSN

6525-01-012-9686

View More Info

146-4890

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129686

NSN

6525-01-012-9686

MFG

EASTMAN KODAK COMPANY DBA KODAK

Description

(NON-CORE DATA) UNIT PACKAGE QUANTITY: 1
COVER MATERIAL: ALUMINUM
FRONT PANEL MATERIAL: ALUMINUM
III PART NAME ASSIGNED BY CONTROLLING AGENCY: CASSETTE RADIOGRAPHIC FILM LIGHTWEIGHT 35X43 CM ALUMINUM COVER
III SUPPLEMENTARY FEATURES: W/O GRID; DAYLIGHT INSPECTION WINDOW ON BACK COVER
INTENSIFYING SCREEN QUANTITY: 2
LENGTH: 43.0 CENTIMETERS NOMINAL
RATED SPEED: HIGH
SPECIAL FEATURES: MOUNTED IN ALUMINUM,CORROSION-RESISTING STEEL,OR POLYURETHANE FRAMES JOINED BY SUITABLE HINGES;SCRATCH RESISTANT VINYL COVERED TUBE SIDE,(FRONT SIDE); WITH FAIL SAFE,FLUSH MOUNTED,LATCHING SYSTEM; DESIGNED TO ENSURE PROPER TIGHTNESS AND CONTACT OF
WIDTH: 35.0 CENTIMETERS NOMINAL
~1: SCREENS,WITH ONE COVER HAVING A FOAM BACKING TO ENHANCE THIS TIGHTNESS; BACK COVER CONTAINS SUFFICIENT LEAD TO PRECLUDE EXCESS SCATTERED RADIATION; FOR USE WITH 14 BY 17 INCH RADIOGRAPHIC FILM

1616671

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129686

NSN

6525-01-012-9686

View More Info

1616671

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129686

NSN

6525-01-012-9686

MFG

EASTMAN KODAK COMPANY DBA KODAK

Description

(NON-CORE DATA) UNIT PACKAGE QUANTITY: 1
COVER MATERIAL: ALUMINUM
FRONT PANEL MATERIAL: ALUMINUM
III PART NAME ASSIGNED BY CONTROLLING AGENCY: CASSETTE RADIOGRAPHIC FILM LIGHTWEIGHT 35X43 CM ALUMINUM COVER
III SUPPLEMENTARY FEATURES: W/O GRID; DAYLIGHT INSPECTION WINDOW ON BACK COVER
INTENSIFYING SCREEN QUANTITY: 2
LENGTH: 43.0 CENTIMETERS NOMINAL
RATED SPEED: HIGH
SPECIAL FEATURES: MOUNTED IN ALUMINUM,CORROSION-RESISTING STEEL,OR POLYURETHANE FRAMES JOINED BY SUITABLE HINGES;SCRATCH RESISTANT VINYL COVERED TUBE SIDE,(FRONT SIDE); WITH FAIL SAFE,FLUSH MOUNTED,LATCHING SYSTEM; DESIGNED TO ENSURE PROPER TIGHTNESS AND CONTACT OF
WIDTH: 35.0 CENTIMETERS NOMINAL
~1: SCREENS,WITH ONE COVER HAVING A FOAM BACKING TO ENHANCE THIS TIGHTNESS; BACK COVER CONTAINS SUFFICIENT LEAD TO PRECLUDE EXCESS SCATTERED RADIATION; FOR USE WITH 14 BY 17 INCH RADIOGRAPHIC FILM

146-4874

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129687

NSN

6525-01-012-9687

View More Info

146-4874

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129687

NSN

6525-01-012-9687

MFG

EASTMAN KODAK COMPANY DBA KODAK

Description

(NON-CORE DATA) UNIT PACKAGE QUANTITY: 1
COVER MATERIAL: ALUMINUM
FRONT PANEL MATERIAL: ALUMINUM
III PART NAME ASSIGNED BY CONTROLLING AGENCY: CASSETTE RADIOGRAPHIC FILM LIGHTWEIGHT 35X30CM WITHOUT GRID
III SUPPLEMENTARY FEATURES: WITHOUT GRID; WITH FLUSH MOUNTED LIFT-UP LATCH; DAYLIGHT INSPECTION WINDOW IN BACK COVER; LIGHTWEIGHT
INTENSIFYING SCREEN QUANTITY: 2
LENGTH: 35.0 CENTIMETERS NOMINAL
RATED SPEED: HIGH
SPECIAL FEATURES: MOUNTED IN ALUMINUM OR POLYURETHANE FRAME JOINED BY A SUITABLE HINGE OR HINGES; SCRATCH RESISTANT VINYL COVERED ON TUBE SIDE W/A FAIL-SAFE,FLUSH MOUNTED,LATCHING SYSTEM ON OPPOSITE SIDE OF HINGE; ONE COVER W/FOAM BACKING; BACK COVER CONTAINS SUFFICIENT
WIDTH: 30.0 CENTIMETERS NOMINAL
~1: LEAD TO PRECLUDE EXCESS SCATTERED RADIATION

8809469

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129687

NSN

6525-01-012-9687

View More Info

8809469

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129687

NSN

6525-01-012-9687

MFG

EASTMAN KODAK COMPANY DBA KODAK

Description

(NON-CORE DATA) UNIT PACKAGE QUANTITY: 1
COVER MATERIAL: ALUMINUM
FRONT PANEL MATERIAL: ALUMINUM
III PART NAME ASSIGNED BY CONTROLLING AGENCY: CASSETTE RADIOGRAPHIC FILM LIGHTWEIGHT 35X30CM WITHOUT GRID
III SUPPLEMENTARY FEATURES: WITHOUT GRID; WITH FLUSH MOUNTED LIFT-UP LATCH; DAYLIGHT INSPECTION WINDOW IN BACK COVER; LIGHTWEIGHT
INTENSIFYING SCREEN QUANTITY: 2
LENGTH: 35.0 CENTIMETERS NOMINAL
RATED SPEED: HIGH
SPECIAL FEATURES: MOUNTED IN ALUMINUM OR POLYURETHANE FRAME JOINED BY A SUITABLE HINGE OR HINGES; SCRATCH RESISTANT VINYL COVERED ON TUBE SIDE W/A FAIL-SAFE,FLUSH MOUNTED,LATCHING SYSTEM ON OPPOSITE SIDE OF HINGE; ONE COVER W/FOAM BACKING; BACK COVER CONTAINS SUFFICIENT
WIDTH: 30.0 CENTIMETERS NOMINAL
~1: LEAD TO PRECLUDE EXCESS SCATTERED RADIATION

146-4619

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129688

NSN

6525-01-012-9688

View More Info

146-4619

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129688

NSN

6525-01-012-9688

MFG

EASTMAN KODAK COMPANY DBA KODAK

Description

(NON-CORE DATA) UNIT PACKAGE QUANTITY: 1
COVER MATERIAL: ALUMINUM
FRONT PANEL MATERIAL: ALUMINUM
III PART NAME ASSIGNED BY CONTROLLING AGENCY: CASSETTE RADIOGRAPHIC FILM LIGHTWEIGHT 24X30 CM ALUMINUM COVER
III SUPPLEMENTARY FEATURES: W/O GRID; DAYLIGHT INSPECTION WINDOW ON BACK COVER
INTENSIFYING SCREEN QUANTITY: 2
LENGTH: 30.0 CENTIMETERS NOMINAL
RATED SPEED: HIGH
SPECIAL FEATURES: SCRATCH RESISTANT VINYL COVERING; FOR USE W/STOCK LISTED FILM OF SAME DIMENSIONS; 24 BY 30 CM
WIDTH: 24.0 CENTIMETERS NOMINAL

1831601

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129688

NSN

6525-01-012-9688

View More Info

1831601

CASSETTE,RADIOGRAPHIC FILM

NSN, MFG P/N

6525010129688

NSN

6525-01-012-9688

MFG

EASTMAN KODAK COMPANY DBA KODAK

Description

(NON-CORE DATA) UNIT PACKAGE QUANTITY: 1
COVER MATERIAL: ALUMINUM
FRONT PANEL MATERIAL: ALUMINUM
III PART NAME ASSIGNED BY CONTROLLING AGENCY: CASSETTE RADIOGRAPHIC FILM LIGHTWEIGHT 24X30 CM ALUMINUM COVER
III SUPPLEMENTARY FEATURES: W/O GRID; DAYLIGHT INSPECTION WINDOW ON BACK COVER
INTENSIFYING SCREEN QUANTITY: 2
LENGTH: 30.0 CENTIMETERS NOMINAL
RATED SPEED: HIGH
SPECIAL FEATURES: SCRATCH RESISTANT VINYL COVERING; FOR USE W/STOCK LISTED FILM OF SAME DIMENSIONS; 24 BY 30 CM
WIDTH: 24.0 CENTIMETERS NOMINAL

652500C959035

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010132193

NSN

6525-01-013-2193

View More Info

652500C959035

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010132193

NSN

6525-01-013-2193

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 140000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959035
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.5 MM SQ; 1.5 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS TUNGSTEN 130 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 0.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: TUNGSTEN
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 130.0 KILOVOLTS

S21027

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010132193

NSN

6525-01-013-2193

View More Info

S21027

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010132193

NSN

6525-01-013-2193

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 140000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959035
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.5 MM SQ; 1.5 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS TUNGSTEN 130 KILOVOLTS
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 0.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: TUNGSTEN
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 130.0 KILOVOLTS

652500C959037

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010132194

NSN

6525-01-013-2194

View More Info

652500C959037

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010132194

NSN

6525-01-013-2194

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959037
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 1.0 MM SQ; 2.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS FOCAL SPOT SIZE 1.0;2.0MM SQ
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 90.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 130.0 KILOVOLTS