My Quote Request
5925000041833
20 Products
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000041833
NSN
5925-00-004-1833
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 2 ALARM
BODY LENGTH: 1.750 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.625 INCHES NOMINAL
BUSHING LENGTH: 0.290 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.245 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 400.0
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 800.0 AC SINGLE LOCATION
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.718 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPECIAL FEATURES: THREADED BUSHING MOUNTED
SWITCH CONTACT ARRANGEMENT: DOUBLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 7.0 AC AND 7.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TURRET
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 230.0 AC AND 28.0 DC
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.080 MINIMUM AT 200 PCT AND 2.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0
0
CIRCUIT BREAKER
NSN
5925-00-004-1833
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 2 ALARM
BODY LENGTH: 1.750 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.625 INCHES NOMINAL
BUSHING LENGTH: 0.290 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.245 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 400.0
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 800.0 AC SINGLE LOCATION
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.718 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPECIAL FEATURES: THREADED BUSHING MOUNTED
SWITCH CONTACT ARRANGEMENT: DOUBLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 7.0 AC AND 7.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TURRET
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 230.0 AC AND 28.0 DC
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.080 MINIMUM AT 200 PCT AND 2.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0
0
n/a
NSN, MFG P/N
5925000017241
NSN
5925-00-001-7241
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 0.750 INCHES NOMINAL
BODY STYLE: SINGLE POLE TYPE
BODY WIDTH: 0.562 INCHES NOMINAL
BUSHING LENGTH: 0.359 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.887 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT
FREQUENCY IN HERTZ: 400.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.5 AMPERES AC AND 1.5 AMPERES DC
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 800.0 AC AND 800.0 DC
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.358 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.438 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC AND 30.0 DC
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS MAXIMUM
TRIP RELEASE CHARACTERISTIC: TIME DELAY
TRIP RELEASE METHOD: THERMAL
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 145.0
0
n/a
NSN
5925-00-001-7241
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 0.750 INCHES NOMINAL
BODY STYLE: SINGLE POLE TYPE
BODY WIDTH: 0.562 INCHES NOMINAL
BUSHING LENGTH: 0.359 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.887 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT
FREQUENCY IN HERTZ: 400.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.5 AMPERES AC AND 1.5 AMPERES DC
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 800.0 AC AND 800.0 DC
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.358 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.438 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC AND 30.0 DC
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS MAXIMUM
TRIP RELEASE CHARACTERISTIC: TIME DELAY
TRIP RELEASE METHOD: THERMAL
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 145.0
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000034660
NSN
5925-00-003-4660
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
ARC QUENCHING METHOD: MAGNETIC BLOWOUT
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FRAGILITY FACTOR: MODERATELY RUGGED
FREQUENCY IN HERTZ: 60.0
INTERNAL TRIP RELEASE CONFIGURATION: RELAY TRIP THIRD LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP FIRST LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SECOND LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC AND 25.0 MILLIAMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC AND 2000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 125.0 DC THIRD LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC FIRST LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SECOND LOCATION
POLE QUANTITY: 3
RESET METHOD: MANUAL
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 8 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.750 MINIMUM AT 150 PCT AND 2.900 MAXIMUM AT 150 PCT AND 0.300 MINIMUM AT 200 P
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0
~1: CT AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS
0
CIRCUIT BREAKER
NSN
5925-00-003-4660
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
ARC QUENCHING METHOD: MAGNETIC BLOWOUT
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FRAGILITY FACTOR: MODERATELY RUGGED
FREQUENCY IN HERTZ: 60.0
INTERNAL TRIP RELEASE CONFIGURATION: RELAY TRIP THIRD LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP FIRST LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SECOND LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC AND 25.0 MILLIAMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC AND 2000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 125.0 DC THIRD LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC FIRST LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SECOND LOCATION
POLE QUANTITY: 3
RESET METHOD: MANUAL
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 8 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.750 MINIMUM AT 150 PCT AND 2.900 MAXIMUM AT 150 PCT AND 0.300 MINIMUM AT 200 P
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0
~1: CT AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000038223
NSN
5925-00-003-8223
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
ARC QUENCHING METHOD: MAGNETIC BLOWOUT
BODY HEIGHT: 2.678 INCHES MINIMUM AND 2.698 INCHES MAXIMUM
BODY LENGTH: 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY STYLE: 9A SINGLE POLE TYPE
BODY WIDTH: 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
BOSS HEIGHT: 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
FRAGILITY FACTOR: MODERATELY RUGGED
FREQUENCY IN HERTZ: 60.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE AND 4 UNTHREADED HOLE
NOMINAL THREAD SIZE: 0.164 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 2 COMPRESSION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.350 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0
UNTHREADED MOUNTING HOLE DIAMETER: 0.190 INCHES NOMINAL
0
CIRCUIT BREAKER
NSN
5925-00-003-8223
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
ARC QUENCHING METHOD: MAGNETIC BLOWOUT
BODY HEIGHT: 2.678 INCHES MINIMUM AND 2.698 INCHES MAXIMUM
BODY LENGTH: 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY STYLE: 9A SINGLE POLE TYPE
BODY WIDTH: 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
BOSS HEIGHT: 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
FRAGILITY FACTOR: MODERATELY RUGGED
FREQUENCY IN HERTZ: 60.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE AND 4 UNTHREADED HOLE
NOMINAL THREAD SIZE: 0.164 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 2 COMPRESSION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.350 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0
UNTHREADED MOUNTING HOLE DIAMETER: 0.190 INCHES NOMINAL
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000046343
NSN
5925-00-004-6343
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0
INTERNAL TRIP RELEASE CONFIGURATION: RELAY TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC AND 15.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: ANY ACCEPTABLE
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 230.0 AC AND 115.0 DC ALL LOCATIONS
OVERALL HEIGHT: 1.500 INCHES NOMINAL
OVERALL LENGTH: 4.443 INCHES NOMINAL
OVERALL WIDTH: 1.750 INCHES NOMINAL
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: ANY ACCEPTABLE
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0
UNTHREADED MOUNTING HOLE DIAMETER: 0.218 INCHES NOMINAL
0
CIRCUIT BREAKER
NSN
5925-00-004-6343
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0
INTERNAL TRIP RELEASE CONFIGURATION: RELAY TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC AND 15.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: ANY ACCEPTABLE
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 230.0 AC AND 115.0 DC ALL LOCATIONS
OVERALL HEIGHT: 1.500 INCHES NOMINAL
OVERALL LENGTH: 4.443 INCHES NOMINAL
OVERALL WIDTH: 1.750 INCHES NOMINAL
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: ANY ACCEPTABLE
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0
UNTHREADED MOUNTING HOLE DIAMETER: 0.218 INCHES NOMINAL
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000046417
NSN
5925-00-004-6417
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.189 INCHES MAXIMUM
BODY STYLE: 7A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES MAXIMUM
BUSHING LENGTH: 0.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.438 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 0.181 INCHES NOMINAL
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 70.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 6000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.250 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 25.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 60.000 MAXIMUM AT 200 PCT AND 2.000 MINIMUM AT 400 PCT AND 7.000 MAXIMUM AT 400 PCT
TRIP RELEASE AMBIENT TEMP RATING: -55.0 DEG CELSIUS MINIMUM SINGLE LOCATION AND 125.0 DEG CELSIUS MAXIMUM
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
ULTIMATE TRIP TIME PER POLE IN SECONDS: 3600.000 MAXIMUM SINGLE LOCATION
0
CIRCUIT BREAKER
NSN
5925-00-004-6417
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.189 INCHES MAXIMUM
BODY STYLE: 7A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES MAXIMUM
BUSHING LENGTH: 0.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.438 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 0.181 INCHES NOMINAL
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 70.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 6000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.250 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 25.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 60.000 MAXIMUM AT 200 PCT AND 2.000 MINIMUM AT 400 PCT AND 7.000 MAXIMUM AT 400 PCT
TRIP RELEASE AMBIENT TEMP RATING: -55.0 DEG CELSIUS MINIMUM SINGLE LOCATION AND 125.0 DEG CELSIUS MAXIMUM
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION
ULTIMATE TRIP TIME PER POLE IN SECONDS: 3600.000 MAXIMUM SINGLE LOCATION
0
n/a
NSN, MFG P/N
5925000053151
NSN
5925-00-005-3151
Description
n/a
0
n/a
NSN, MFG P/N
5925000053155
NSN
5925-00-005-3155
Description
n/a
0
n/a
NSN, MFG P/N
5925000058791
NSN
5925-00-005-8791
Description
n/a
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000061418
NSN
5925-00-006-1418
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
ARC QUENCHING METHOD: MAGNETIC BLOWOUT
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FRAGILITY FACTOR: MODERATELY RUGGED
FREQUENCY IN HERTZ: 60.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 110.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.200 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0
0
CIRCUIT BREAKER
NSN
5925-00-006-1418
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
ARC QUENCHING METHOD: MAGNETIC BLOWOUT
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FRAGILITY FACTOR: MODERATELY RUGGED
FREQUENCY IN HERTZ: 60.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 110.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.200 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0
0
n/a
NSN, MFG P/N
5925000067064
NSN
5925-00-006-7064
Description
n/a
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000070708
NSN
5925-00-007-0708
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY HEIGHT: 3.000 INCHES NOMINAL
BODY LENGTH: 6.000 INCHES NOMINAL
BODY STYLE: 9A SINGLE POLE TYPE
BODY WIDTH: 1.500 INCHES NOMINAL
BOSS HEIGHT: 0.156 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 5.125 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 5.125 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.250 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 60.0 AMPERES AC AND 60.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC AND 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC AND 125.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 30.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0
UNTHREADED MOUNTING HOLE DIAMETER: 0.172 INCHES NOMINAL
0
CIRCUIT BREAKER
NSN
5925-00-007-0708
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY HEIGHT: 3.000 INCHES NOMINAL
BODY LENGTH: 6.000 INCHES NOMINAL
BODY STYLE: 9A SINGLE POLE TYPE
BODY WIDTH: 1.500 INCHES NOMINAL
BOSS HEIGHT: 0.156 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 5.125 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 5.125 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.250 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 60.0 AMPERES AC AND 60.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC AND 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC AND 125.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 30.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0
UNTHREADED MOUNTING HOLE DIAMETER: 0.172 INCHES NOMINAL
0
n/a
NSN, MFG P/N
5925000077387
NSN
5925-00-007-7387
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
ARC QUENCHING METHOD: MAGNETIC BLOWOUT
BODY LENGTH: 2.470 INCHES MINIMUM AND 2.530 INCHES MAXIMUM
BODY STYLE: MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.470 INCHES MINIMUM AND 1.530 INCHES MAXIMUM
BOSS HEIGHT: 0.115 INCHES MINIMUM AND 0.215 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.908 INCHES MINIMUM AND 1.968 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.032 INCHES MINIMUM AND 2.092 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FRAGILITY FACTOR: MODERATELY RUGGED
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT AND EXPLOSION PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES DC
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 DC
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.645 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPECIAL HANDLING FEATURE: MAGNETIC
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS
TRIP RELEASE METHOD: MAGNETIC
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0
UNPACKAGED UNIT WEIGHT: 8.000 OUNCES
0
n/a
NSN
5925-00-007-7387
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
ARC QUENCHING METHOD: MAGNETIC BLOWOUT
BODY LENGTH: 2.470 INCHES MINIMUM AND 2.530 INCHES MAXIMUM
BODY STYLE: MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.470 INCHES MINIMUM AND 1.530 INCHES MAXIMUM
BOSS HEIGHT: 0.115 INCHES MINIMUM AND 0.215 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.908 INCHES MINIMUM AND 1.968 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.032 INCHES MINIMUM AND 2.092 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FRAGILITY FACTOR: MODERATELY RUGGED
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT AND EXPLOSION PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES DC
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 DC
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.645 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPECIAL HANDLING FEATURE: MAGNETIC
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS
TRIP RELEASE METHOD: MAGNETIC
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0
UNPACKAGED UNIT WEIGHT: 8.000 OUNCES
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000079070
NSN
5925-00-007-9070
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY HEIGHT: 2.359 INCHES NOMINAL
BODY LENGTH: 3.281 INCHES NOMINAL
BODY STYLE: 6C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.000 INCHES NOMINAL
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 18.000 MINIMUM AT 200 PCT AND 125.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0
UNTHREADED MOUNTING HOLE DIAMETER: 0.187 INCHES NOMINAL
0
CIRCUIT BREAKER
NSN
5925-00-007-9070
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY HEIGHT: 2.359 INCHES NOMINAL
BODY LENGTH: 3.281 INCHES NOMINAL
BODY STYLE: 6C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.000 INCHES NOMINAL
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 18.000 MINIMUM AT 200 PCT AND 125.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0
UNTHREADED MOUNTING HOLE DIAMETER: 0.187 INCHES NOMINAL
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000079396
NSN
5925-00-007-9396
Description
POLE QUANTITY: 3
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000079397
NSN
5925-00-007-9397
Description
POLE QUANTITY: 3
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000080511
NSN
5925-00-008-0511
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY HEIGHT: 2.656 INCHES NOMINAL
BODY LENGTH: 7.000 INCHES NOMINAL
BODY STYLE: 11B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 3.000 INCHES NOMINAL
BOSS HEIGHT: 0.187 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 5.750 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.375 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 5.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.375 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 150.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 COMPRESSION
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS MAXIMUM ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.281 INCHES NOMINAL
0
CIRCUIT BREAKER
NSN
5925-00-008-0511
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY HEIGHT: 2.656 INCHES NOMINAL
BODY LENGTH: 7.000 INCHES NOMINAL
BODY STYLE: 11B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 3.000 INCHES NOMINAL
BOSS HEIGHT: 0.187 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 5.750 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.375 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 5.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.375 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 150.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 10000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 COMPRESSION
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS MAXIMUM ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.281 INCHES NOMINAL
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000080535
NSN
5925-00-008-0535
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
ARC QUENCHING METHOD: AIR
BODY LENGTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.531 INCHES MINIMUM AND 0.593 INCHES MAXIMUM
BUSHING LENGTH: 0.219 INCHES MINIMUM AND 0.281 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.672 INCHES MINIMUM AND 0.734 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FRAGILITY FACTOR: MODERATELY RUGGED
FREQUENCY IN HERTZ: 400.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT AND VIBRATIONPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 4.0 AMPERES AC AND 4.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC AND 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.919 INCHES MINIMUM AND 1.981 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 200.0 AC AND 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 145.0
UNPACKAGED UNIT WEIGHT: 38.0 GRAMS
0
CIRCUIT BREAKER
NSN
5925-00-008-0535
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
ARC QUENCHING METHOD: AIR
BODY LENGTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.531 INCHES MINIMUM AND 0.593 INCHES MAXIMUM
BUSHING LENGTH: 0.219 INCHES MINIMUM AND 0.281 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.672 INCHES MINIMUM AND 0.734 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FRAGILITY FACTOR: MODERATELY RUGGED
FREQUENCY IN HERTZ: 400.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT AND VIBRATIONPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 4.0 AMPERES AC AND 4.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC AND 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.919 INCHES MINIMUM AND 1.981 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 200.0 AC AND 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 145.0
UNPACKAGED UNIT WEIGHT: 38.0 GRAMS
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000080548
NSN
5925-00-008-0548
Description
CIRCUIT BREAKER
0
CIRCUIT BREAKER
NSN, MFG P/N
5925000086617
NSN
5925-00-008-6617
Description
CIRCUIT BREAKER