IEL11161-15.0-01

CIRCUIT BREAKER

NSN, MFG P/N

5925013275726

NSN

5925-01-327-5726

View More Info

IEL11161-15.0-01

CIRCUIT BREAKER

NSN, MFG P/N

5925013275726

NSN

5925-01-327-5726

MFG

PERKIN-ELMER CORP THE

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.485 INCHES MINIMUM AND 2.495 INCHES MAXIMUM
BODY STYLE: 17B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
BOSS HEIGHT: 0.135 INCHES MINIMUM AND 0.145 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.933 INCHES MINIMUM AND 1.943 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.055 INCHES MINIMUM AND 2.065 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCKPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.996 INCHES MINIMUM AND 2.006 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.300 MINIMUM AT 200 PCT AND 3.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

28075311

CIRCUIT BREAKER

NSN, MFG P/N

5925013275727

NSN

5925-01-327-5727

View More Info

28075311

CIRCUIT BREAKER

NSN, MFG P/N

5925013275727

NSN

5925-01-327-5727

MFG

HENLEY MARINE INC SAN DIEGO OPNS

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.485 INCHES MINIMUM AND 2.495 INCHES MAXIMUM
BODY STYLE: 17B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
BOSS HEIGHT: 0.135 INCHES MINIMUM AND 0.145 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.933 INCHES MINIMUM AND 1.943 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.055 INCHES MINIMUM AND 2.065 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCKPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.996 INCHES MINIMUM AND 2.006 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.130 MINIMUM AT 200 PCT AND 3.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

IEL11-1-61-25.0-01-V

CIRCUIT BREAKER

NSN, MFG P/N

5925013275727

NSN

5925-01-327-5727

View More Info

IEL11-1-61-25.0-01-V

CIRCUIT BREAKER

NSN, MFG P/N

5925013275727

NSN

5925-01-327-5727

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.485 INCHES MINIMUM AND 2.495 INCHES MAXIMUM
BODY STYLE: 17B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
BOSS HEIGHT: 0.135 INCHES MINIMUM AND 0.145 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.933 INCHES MINIMUM AND 1.943 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.055 INCHES MINIMUM AND 2.065 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCKPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.996 INCHES MINIMUM AND 2.006 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.130 MINIMUM AT 200 PCT AND 3.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

IEL11161-25.0-01

CIRCUIT BREAKER

NSN, MFG P/N

5925013275727

NSN

5925-01-327-5727

View More Info

IEL11161-25.0-01

CIRCUIT BREAKER

NSN, MFG P/N

5925013275727

NSN

5925-01-327-5727

MFG

PERKIN-ELMER CORP THE

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.485 INCHES MINIMUM AND 2.495 INCHES MAXIMUM
BODY STYLE: 17B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
BOSS HEIGHT: 0.135 INCHES MINIMUM AND 0.145 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.933 INCHES MINIMUM AND 1.943 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.055 INCHES MINIMUM AND 2.065 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCKPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.996 INCHES MINIMUM AND 2.006 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.130 MINIMUM AT 200 PCT AND 3.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

053283

CIRCUIT BREAKER

NSN, MFG P/N

5925013275728

NSN

5925-01-327-5728

View More Info

053283

CIRCUIT BREAKER

NSN, MFG P/N

5925013275728

NSN

5925-01-327-5728

MFG

MILLER ELECTRIC MFG CO

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.140 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.570 INCHES NOMINAL
BUSHING LENGTH: 0.400 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III UNPACKAGED UNIT WEIGHT: 1.000 OUNCES
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC AND 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC AND 2000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.220 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 27
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 70.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0 SINGLE LOCATION

45-700-IG1-P10-15A

CIRCUIT BREAKER

NSN, MFG P/N

5925013275728

NSN

5925-01-327-5728

View More Info

45-700-IG1-P10-15A

CIRCUIT BREAKER

NSN, MFG P/N

5925013275728

NSN

5925-01-327-5728

MFG

OAKLAND INDUSTRIES LTD DBA E-T-A CIRCUIT BREAKERS

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.140 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.570 INCHES NOMINAL
BUSHING LENGTH: 0.400 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III UNPACKAGED UNIT WEIGHT: 1.000 OUNCES
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC AND 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC AND 2000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.220 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 27
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 70.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0 SINGLE LOCATION

45-700-P10-F31-RS04 15AMP

CIRCUIT BREAKER

NSN, MFG P/N

5925013275728

NSN

5925-01-327-5728

View More Info

45-700-P10-F31-RS04 15AMP

CIRCUIT BREAKER

NSN, MFG P/N

5925013275728

NSN

5925-01-327-5728

MFG

BRUNSWICK CORPORATION DBA MERCURY MARINE DIV MERCURY MARINE

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.140 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.570 INCHES NOMINAL
BUSHING LENGTH: 0.400 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III UNPACKAGED UNIT WEIGHT: 1.000 OUNCES
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC AND 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC AND 2000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.220 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 27
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 70.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0 SINGLE LOCATION

AP-1-1-71F-1751

CIRCUIT BREAKER

NSN, MFG P/N

5925013276596

NSN

5925-01-327-6596

View More Info

AP-1-1-71F-1751

CIRCUIT BREAKER

NSN, MFG P/N

5925013276596

NSN

5925-01-327-6596

MFG

SENSATA TECHNOLOGIES MARYLAND INC

MAL36700

CIRCUIT BREAKER

NSN, MFG P/N

5925013276696

NSN

5925-01-327-6696

View More Info

MAL36700

CIRCUIT BREAKER

NSN, MFG P/N

5925013276696

NSN

5925-01-327-6696

MFG

SQUARE D CO CEDAR RAPIDS MFG PLANT

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS: 3500.0 TO 7000.0 AC AND 3500.0 TO 7000.0 DC ALL LOCATIONS
BODY HEIGHT: 4.530 INCHES NOMINAL
BODY LENGTH: 14.000 INCHES NOMINAL
BODY STYLE: 11B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 9.000 INCHES NOMINAL
BOSS HEIGHT: 1.970 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 10.690 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 3.000 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 10.690 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.500 INCHES NOMINAL
FEATURES PROVIDED: ADJUSTABLE TRIP RELEASE
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 700.0 AMPERES AC AND 700.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 22000.0 AC AND 14000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 250.0 DC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.196 INCHES NOMINAL

342C891H20

CIRCUIT BREAKER

NSN, MFG P/N

5925013276839

NSN

5925-01-327-6839

View More Info

342C891H20

CIRCUIT BREAKER

NSN, MFG P/N

5925013276839

NSN

5925-01-327-6839

MFG

NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS CORPORATION ELECTRONIC SYSTEMS

T11-1-3.00A-02-11

CIRCUIT BREAKER

NSN, MFG P/N

5925013276998

NSN

5925-01-327-6998

View More Info

T11-1-3.00A-02-11

CIRCUIT BREAKER

NSN, MFG P/N

5925013276998

NSN

5925-01-327-6998

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

BODY STYLE: 2A SINGLE POLE TYPE
BODY WIDTH: 0.680 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.375 INCHES NOMINAL
FREQUENCY IN HERTZ: 50.0 OR 60.0 SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 3.0 AMPERES DC SINGLE LOCATION
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.540 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
POLE QUANTITY: 1

AM12-4-250-14-400

CIRCUIT BREAKER

NSN, MFG P/N

5925013277421

NSN

5925-01-327-7421

View More Info

AM12-4-250-14-400

CIRCUIT BREAKER

NSN, MFG P/N

5925013277421

NSN

5925-01-327-7421

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 4.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.611 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 28.000 MINIMUM AT 200 PCT AND 99.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION

APL-1-1-43-402

CIRCUIT BREAKER

NSN, MFG P/N

5925013277421

NSN

5925-01-327-7421

View More Info

APL-1-1-43-402

CIRCUIT BREAKER

NSN, MFG P/N

5925013277421

NSN

5925-01-327-7421

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 4.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.611 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 28.000 MINIMUM AT 200 PCT AND 99.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION

NZ12-630+RH12+SVB+U

CIRCUIT BREAKER

NSN, MFG P/N

5925013278712

NSN

5925-01-327-8712

View More Info

NZ12-630+RH12+SVB+U

CIRCUIT BREAKER

NSN, MFG P/N

5925013278712

NSN

5925-01-327-8712

MFG

DE LA RUE GIORI S.A.

209-2-1REC4-62F-4-9-63.6-A

CIRCUIT BREAKER

NSN, MFG P/N

5925013279716

NSN

5925-01-327-9716

View More Info

209-2-1REC4-62F-4-9-63.6-A

CIRCUIT BREAKER

NSN, MFG P/N

5925013279716

NSN

5925-01-327-9716

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

BODY LENGTH: 5.800 INCHES MAXIMUM
BODY WIDTH: 2.072 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 63.6 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2

KB3250F

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925013279823

NSN

5925-01-327-9823

View More Info

KB3250F

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925013279823

NSN

5925-01-327-9823

MFG

OLIN CORP OLIN RESEARCH CENTER

Description

III END ITEM IDENTIFICATION: WESTINGHOUSE CDP PANELBOARDS

3120-F323-P7T1-R12FB

CIRCUIT BREAKER

NSN, MFG P/N

5925013280293

NSN

5925-01-328-0293

View More Info

3120-F323-P7T1-R12FB

CIRCUIT BREAKER

NSN, MFG P/N

5925013280293

NSN

5925-01-328-0293

MFG

OAKLAND INDUSTRIES LTD DBA E-T-A CIRCUIT BREAKERS

203-2-1-65-102-4-1-13

CIRCUIT BREAKER

NSN, MFG P/N

5925013280322

NSN

5925-01-328-0322

View More Info

203-2-1-65-102-4-1-13

CIRCUIT BREAKER

NSN, MFG P/N

5925013280322

NSN

5925-01-328-0322

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY HEIGHT: 1.770 INCHES MAXIMUM
BODY LENGTH: 1.970 INCHES MINIMUM AND 2.030 INCHES MAXIMUM
BODY STYLE: 10A SINGLE POLE TYPE
BODY WIDTH: 0.890 INCHES MINIMUM AND 0.950 INCHES MAXIMUM
BOSS HEIGHT: 0.095 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 50.0 OR 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 CLIP
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPECIAL FEATURES: TOGGLE EQUIPPED WITH ILLUMINATED FEATURE
TERMINAL TYPE AND QUANTITY: 2 TAB, SOLDER LUG
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 MINIMUM AT 200 PCT AND 6.500 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

203-11-1-65F-203-1-1

CIRCUIT BREAKER

NSN, MFG P/N

5925013280325

NSN

5925-01-328-0325

View More Info

203-11-1-65F-203-1-1

CIRCUIT BREAKER

NSN, MFG P/N

5925013280325

NSN

5925-01-328-0325

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY HEIGHT: 1.770 INCHES MAXIMUM
BODY LENGTH: 1.970 INCHES MINIMUM AND 2.030 INCHES MAXIMUM
BODY STYLE: 20B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.510 INCHES MINIMUM AND 1.570 INCHES MAXIMUM
BOSS HEIGHT: 0.095 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.595 INCHES MINIMUM AND 0.655 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 CLIP
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 TAB, SOLDER LUG
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 1.000 MINIMUM AT 200 PCT AND 5.500 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

UPG-6666-1-64-253-01

CIRCUIT BREAKER

NSN, MFG P/N

5925013280326

NSN

5925-01-328-0326

View More Info

UPG-6666-1-64-253-01

CIRCUIT BREAKER

NSN, MFG P/N

5925013280326

NSN

5925-01-328-0326

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO AND AT POLE THREE
BODY LENGTH: 1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.015 INCHES MAXIMUM
BOSS HEIGHT: 0.115 INCHES MINIMUM AND 0.145 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.515 INCHES MINIMUM AND 1.545 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.645 INCHES MINIMUM AND 1.675 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED AND TWO AND THREE LINKED
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3500.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 8 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.032 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 4
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 8 TAB W/SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.150 MINIMUM AT 200 PCT AND 1.900 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS